摘要 测量不确定度是测量技术的重要概念,只要涉及到测量数据的场合,都不可避免地牵涉到测量不确定度。本文介绍了人造板静曲强度的测量不确定度评定的方法,并对实验室自制定向刨花板静曲强度进行测量不确定度的评定,得到实验室自制定向刨花板静曲强度为:σb=(60±3)MPa,其中扩展不确定度的包含因子kp=1.985,置信概率p=95%。 The measurement uncertainty is a very important concept,which is used every where to be measured.The method of uncertainty evaluation in modulus of rupture test of wood-based panel was introduced in this paper.According to evaluating the uncertainty in modulus of rupture tests of oriented strand board made in Laboratory,the value of MOR(σb) was(60±3)MPa,and coverage factor(kp),confidence probability(p) of expanded uncertainty were 1.985 and 95% respectively.
作者 周兆兵 张洋
出处 《林业科技开发》 2010年第4期29-31,共3页 China Forestry Science and Technology
基金 林业公益性行业科研专项(编号:200704006)
关键词 人造板 静曲强度 不确定度 定向刨花板 wood-based Panel MOR uncertainty oriented strand board
  • 相关文献

参考文献8

二级参考文献5

  • 1张剑,卢志刚,袁敏,李翔,戴东情.气体分析法测定人造板甲醛释放量的不确定度评定[J].中国人造板,2007,14(5):10-12. 被引量:6
  • 2国家质量技术监督局.JJF1059-1999测量不确定度评定与表示[S].北京:中国计量出版社,1999..
  • 3国家质量技术监督局计量司.测量不确定度评定与指南[M].北京:中国计量出版社,2000.
  • 4EN717 -2 : 1994 Wood-base panels-Determination of formaidehyde release-Part2 : Formaidehyde release by the gas analysis method[ S].
  • 5GB/T601-202,化学试剂标准滴定溶液的制备[S].