An untuned MA-loaded cavity for HIRFL-CSR

An untuned MA-loaded cavity for HIRFL-CSR
原文传递
导出
摘要 In order to realize high energy density physics and plasma physics research at HIRFL-CSR, a magnetic alloy (MA)-loaded cavity has been studied. According to the theoretical calculation and simulation for the MA-loaded cavity, we achieved a better result. The MA-loaded cavity had a higher μQf value, with a higher shunt impedance and a higher accelerating gradient. The accelerating gradient was about 95 kV/m at 1.8003 MHz, 130 kV/m at 0.9000 MHz. Compared with the ferrite-loaded cavities that are used at HIRFL-CSR, with about 10 kV/m accelerating gradient, the MA-loaded cavity obviously has an advantage. The results of the theoretical calculation and the simulation, which meet the design requirements are in good agreement. In order to realize high energy density physics and plasma physics research at HIRFL-CSR, a magnetic alloy (MA)-loaded cavity has been studied. According to the theoretical calculation and simulation for the MA-loaded cavity, we achieved a better result. The MA-loaded cavity had a higher μQf value, with a higher shunt impedance and a higher accelerating gradient. The accelerating gradient was about 95 kV/m at 1.8003 MHz, 130 kV/m at 0.9000 MHz. Compared with the ferrite-loaded cavities that are used at HIRFL-CSR, with about 10 kV/m accelerating gradient, the MA-loaded cavity obviously has an advantage. The results of the theoretical calculation and the simulation, which meet the design requirements are in good agreement.
出处 《Chinese Physics C》 SCIE CAS CSCD 2010年第8期1132-1135,共4页 中国物理C(英文版)
关键词 magnetic alloy material untuned MA-loaded cavity accelerating gradient magnetic alloy material, untuned MA-loaded cavity, accelerating gradient
  • 相关文献

参考文献7

  • 1Hulsmann P, Hutter G, Vinzenz W. The Bunch Compressor System for SIS18 AT GSI. EPAC2004. Lucerne, 2004. 1165-1167.
  • 2Mori Y et al. A New Type of RF Cavity for High Intensity Proton Synchrotron Using High Permeability Magnetic Alloy. EPAC98. Stockholm, 1998.
  • 3Ohmori C, Ezura E, Fujieda Met al. High Field-Gradient Cavities Loaded with Magnetic Alloys for Synchrotron. PAC99. New York, 1999. 413-417.
  • 4Ohmoria C, Kanazawa M, Noda K et al. Nuclear Instruments and Methods in Physics Research A, 2005, 547: 249- 258.
  • 5Saito K, Hirota J I, Noda F. Nuclear Instruments and Methods in Physics Research A, 1998, 402:1-13.
  • 6XU Zhe, DUAN Ya-Juan, ZHAO Hong-Wei et al. Nuclear Physics Review, 2008, 25(3): 249-253.
  • 7Watanabe M, Chiba Y, Katayama T et al. Nuclear Instruments and Methods in Physics Research A, 2004, 532: 503- 507.