摘要 论述了适用于各种配电网的故障区段判断和隔离的通用算法。首先针对配电网的结构获得一个网络描述矩阵。在发生故障时,根据安放于馈线分段开关处和主变电所的RTU上报的过电流信息生成一个故障信息矩阵,通过网络描述矩阵和故障信息矩阵的运算得到一个故障判断矩阵,根据故障判断矩阵就可准确地判断和隔离故障区段。给出了若干实例。 A unified algorithm for fault section detection and isolation in distribution system is presented. A describing mattixmust be first established on the basis of the structure of distribution system. When fault occurs. a fault information matrix isformed according to the message from pole-mounted RTU and the RTU in main substation. A fault detecting matrix can beobtained from the above two matrixes. with which the fault section can be detected and isolated correctly. Several examplesrelated to the proposed algorithm are discussed.
出处 《电力系统自动化》 EI CSCD 北大核心 1999年第1期31-33,共3页 Automation of Electric Power Systems
关键词 配电网自动化 故障区域隔离 城市电网 算法 :distribution automation (DA) feeder automation (FA) fault section detection fault section isolation