期刊文献+

PET/CT图像融合的仪器质量控制探讨 被引量:3

Study on Quality Control of PET/CT Image Fusion
下载PDF
导出
摘要 本文主要探讨了PET/CT图像融合设备在PET、CT和PET/CT三个方面的质量控制,得出PET/CT的质量控制是在完善的PET和CT质量控制的基础上,加上PET/CT融合的质量控制才得以实现的。 This paper mainly discusses the quality control of PET/CT image fusion in PET,CT and PET/CT,and draws a conclusion that PET/CT is the integration of PET and CT based on perfect quality control.
作者 王昌军
出处 《中国医疗设备》 2010年第7期103-104,共2页 China Medical Devices
关键词 PET/CT 图像融合 质量控制 配准 PET/CT image fusion quality control registering
  • 相关文献

参考文献5

二级参考文献9

  • 1Beyer T,Townsend DW,Brun T,et al. A combined PET/CT scanner for clinical oncology[J]. J Nucl Med,2000,41:1369-1379.
  • 2Takagi K,Fukazawa T.Cerium-activated Gd2SiO5 single crystal scintillator[J].Appl Phys Lett, 1983,42:43-45.
  • 3Melcher CL, Schweitzer JS. Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator[J].IEEE Trans Nucl Sci,1992,39:502-505.
  • 4Townsend DW.Dual-modality Imaging: combining anatomy and function[J].J Nucl Med,2008,49:938-955.
  • 5Jakoby BW,Bercier Y,Watson CC, et al. Physical performance and clinical workflow of a new LSO HI-REZ PET/CT scanner[J]. 2006 IEEE Nucl Sci Syrup Conf Record,2006,5:3130-3134.
  • 6Surfi S, Kuhn A, Wemer ME, et al. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-offlight imaging capabilities[J].J Nucl Med,2007,48:471-480.
  • 7NEMA.NEMA standards publication:performance measure ments of positron emission tomography[S].NEMA standards publication NU 2-1994.NU 2-1999 and NU 2-2001.
  • 8冯晓刚,洪德明,余晓锷,林木炎.多层面螺旋CT机的应用质量检测与结果分析[J].中国医学计算机成像杂志,2001,7(5):352-354. 被引量:7
  • 9陈盛祖,党亚萍,陶军,耿建华.Discovery LS PET/CT的验收及性能评估[J].中华核医学杂志,2004,24(2):117-120. 被引量:19

共引文献42

同被引文献20

  • 1杨军,吴建伟,艾书月,黄伟.PET-CT的质量控制和质量管理[J].医疗卫生装备,2006,27(9):71-73. 被引量:8
  • 2李天然,赵春雷,钱根年,陈自谦,王楷堂,游学宇,郑春雨.~18F-FDG PET/CT伪影和不常见生理性摄取分析[J].中华核医学杂志,2006,26(5):295-298. 被引量:10
  • 3田嘉禾,张锦明,陈英茂,等.PET/CT诊断学[M].北京:化学工业出版社.2007:247-262.
  • 4田嘉禾.PET、PET/CT诊断学[M].北京:化学工业出版社.2007.335-337.
  • 5Emran AM. New Trends in radio- pharmaceutical synthe is. quality assurance and regulatory control[M].New York. Plemum Press, 1991.
  • 6Chiesa C, De Sanctis V, Crippa F, et al. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose[J].Eur J Nucl Med, 1997,24(11):1380-1389.
  • 7Jackson J,Pan T,Tonkopi E,et al.Implementation of auto- mated tube current modulation in PET/CT:prospective se- lection of a noise index and retrospective patient analysis toensure image quality [J].J Nuel Med Teehnol,2011,39(2): 83-90.
  • 8Lee S,Yoon SW,Yoo SM,et al.Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of ab- domen and pelvis[J].Acta Radiol, 2011,52 (10) : 1101-1106.
  • 9Beyer T,Antoch G,Blodgett T,et al.Dual-modality PET/CT imaging:the effect of respiratory motion on combined image quality in clinical oncology [J].Eur J Nucl Med,2003,30: 588-596.
  • 10Kawashita N,Brito M,Brito S,et al.Glucose uptake,glucose trasporter GLUT4,and glyeolytic enzymes in brown adipose tirrue from rats adapted to a high protein diet [J]. Metabolism, 2002, (51 ) : 1501 - 1505.

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部