摘要 提出一种T接线输电线路零序阻抗参数带电测量新方法。详细介绍了该带电测量方法的测量原理与数学模型,并给出带电测量时T型线路的运行方式,通过获取测量源与利用全球卫星定位系统(GPS)作为异地测量的同步信号。通过数字仿真进行验证,仿真结果表明该带电测量方法是可行的,测量结果准确,完全能满足工程测量要求。 Based on GPS technology,a novel method of live line measuring the zero sequence parameters of multi-terminal transmission lines is proposed.The operation modes of the transmission lines for live line measurement are given.The mathematical model of the new method is explained in detail.The methods to obtain big zero-sequence currents for live line measurement are introduced.In order to realize the synchronization of data acquisition,a GPS is used to obtain an accurate time tag for all the currents and voltages sampled at different substations.The digital simulation results are given.The simulation results prove that the new method can meet the needs of live line measurement of inductance parameters.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2010年第15期65-68,共4页 Power System Protection and Control
关键词 GPS T型输电线路 零序阻抗 带电测量 global positioning system(GPS) multi-terminal transmission line zero sequence impedance live line measurement
  • 相关文献

参考文献9

  • 1束洪春,高峰,陈学允,许承斌.T型输电系统故障测距算法研究[J].中国电机工程学报,1998,18(6):416-420. 被引量:64
  • 2李胜芳,范春菊,郁惟镛.T型支接线路的自适应故障测距算法[J].电工技术学报,2004,19(10):59-64. 被引量:39
  • 3Xia Y Q,David A K,Li K K.High-resistance faults on a multi-terminal lines:--analysis,simulated studies and an adaptive distance relaying scheme[J].IEEE Transactions on Power Delivery,1994,9(1):492-500.
  • 4Toshihisa Funabashi,Hitomi Otoguro,Yoshishige Mizuma.Fault location for high resistance grounded transmission lines[J].IEEE Trans on Power Delivery,1999,14(1):80-85.
  • 5傅知兰.电力系统电气设备选择与实用计算[M].北京:中国电力出版社,2005.
  • 6李建明,朱康.高压电气设备试验方法[M].北京:中国电力出版,2005.
  • 7胡志坚,陈允平,张承学,王立,罗宁.宁夏电网220kV互感线路参数带电测量[J].电力系统自动化,2000,24(17):41-44. 被引量:17
  • 8胡志坚,陈允平,徐玮,梁有伟,龙厚军.基于微分方程的互感线路参数带电测量研究与实现[J].中国电机工程学报,2005,25(2):28-33. 被引量:42
  • 9HU Zhi-jian,CHEN Yun-ping.New method of live line measuring the inductance parameters of transmission lines based on GPS technology[J].IEEE Transactions on Power Delivery,2008,23(3):1288-2195.

二级参考文献21

  • 1董新洲,葛耀中.一种使用两端电气量的高压输电线路故障测距算法[J].电力系统自动化,1995,19(8):47-53. 被引量:79
  • 2陈允平,电力系统自动化,1995年,19卷,2期,38页
  • 3何仰赞,电力系统分析,1992年
  • 4DommelHW著 李永庄 林集明 曾昭华译.电力系统电磁暂态计算理论[M].北京:水利电力出版社,1991..
  • 5何仰赞 温增银 等.电力系统分析[M].武汉华中理工大学出版社,1992..
  • 6Jiang J A, Yang J Z, Lin Y H, et al. An adaptive PMU based fault detection/location technique for transmission lines-Part I:Theory and algorithms. IEEE Trans. on Power Delivery, 2000, 15(2):486-493
  • 7Jiang J A, Lin Y H, Yang J Z, et al. An adaptive PMU based fault detection/location technique for transmission lines-Part II: PMU implementation and performance evaluations. IEEE Trans. on Power Delivery, 2000, 15(2):1136~1146
  • 8Lin Yinghong, Liu Chihwen, Yu Chishan. A new fault locator for three-terminal transmission lines using two-terminal synchronized voltage and current phasors. IEEE Transactions on Power Delivery, 2002, 17(2):452~459
  • 9Olsen R G, Edwards K S. A new method for real-time monitoring of high-voltage transmission-line conductor sag. IEEE Transactions on Power Delivery, 2002, 17(4):1142-1152
  • 10周大敏.一种实用的三端高压输电线路故障测距方法[J].电力自动化设备,1998,18(1):17-20. 被引量:13

共引文献140

同被引文献64

引证文献7

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部