摘要
在FED理论基础上,参考SII烟气伤害模型提出一个考虑烟气温度、能见度和毒性综合作用的人员伤害模型,并在该模型基础上开发基于GIS的火灾烟气危害评价系统。该系统可以确定建筑室内火灾中烟气综合危害分布和毒性分布随时间变化的情况,并得出性能化防火设计重要参数之一ASET,为火灾人员疏散提供参考依据。
Based on the theory of FED, and taking SII smoke damage model as reference, a personal injury model considering the combined action of smoke temperature, visibility and toxici- ty is proposed and a system based on the model and GIS is developed. The system can evaluate the integrated hazards and taxicity changing over time, and get the important parameter of perform-based fire design, available safety egress time, to provide references for evacuation in fire.
出处
《消防科学与技术》
CAS
北大核心
2010年第8期651-655,共5页
Fire Science and Technology
基金
国家"十一五"科技支撑项目"农村建筑防火与抗火技术研究与示范"(2006BAJ06B06)
关键词
烟气
综合危害
评价模型
可用安全疏散时间
smoke
integrated hazards
evaluation model
available safety egress time