期刊文献+

基于Cine扫描的4D-CT图像重建系统设计研究 被引量:1

The Design of 4D-CT Reconstruction System Base on Cine Mode CT Scan
下载PDF
导出
摘要 为了在普通多螺旋CT上实现4D-CT重建,研究中采用VC++程序设计语言和模块化的程序设计方法,开发了基于Cine扫描的4D-CT图像重建系统。利用本系统,根据体表轮廓和肺组织的体积变化确定CT图像在呼吸周期中的相位,按相位分组排序后,实现4D-CT重建,其重建过程不依赖于外在的呼吸监测装置、不受CT机本身的软硬件限制,具有普遍适用性。 To implement 4D - CT reconstruction based on multi - slices CT scanner. A 4D - CT reconstruction software system based on Cine mode CT scan was developed by using VC + + progame language. The phase of each CT slice was determined according to the volume change rule of scanned thoracic cavity and lung tissue during respiration. All of the CT data with same phase, which where acquired in Cine mode, were resorted by the system into a same CT series, and several 3D - CT series with different phases could be gut.Then, all of the resorted multi - phase CT series result in a 4D - CT. The research suggested that time - resolved 4D - CT reconstruction could be implemented with any general multi - slice CT scarmers by using this 4D - CT reconstruction system, the process of the 4D CT data acquisition and reconstruction were independent on the respiration monitoring system and not restricted to the hardware or software of the CT scanner, therefore, it' s a universal 4D - CT reconstruction method.
出处 《医疗装备》 2010年第8期20-23,共4页 Medical Equipment
基金 广州市属高校科技计划项目(08A008) 广州医学院博士留学回国人员基金项目(2010-1-11)
关键词 四维计算机断层图像(4D—CT) 图像重建 电影模式扫描 Four dimensional computed tomography (4D - CT) Image reconstruction Cine mode CT scan
  • 相关文献

参考文献3

二级参考文献14

  • 1张书旭,徐海荣,陈光杰,杨克柽,林生趣,余辉.呼吸运动对靶区三维重建的影响[J].中国医学物理学杂志,2006,23(6):400-404. 被引量:14
  • 2ZHANG Shu-xu,CHEN Guang-jie,ZHOU Ling-hong,YANG Ke-cheng,LIN Sheng-qu.Influences of Motion Artifacts on Three-Dimensional Reconstruction Volume and Conformal Radiotherapy Planning[J].Chinese Journal of Biomedical Engineering(English Edition),2007,16(3):123-130. 被引量:9
  • 3Duan J,Shen S,Fiveash JB,et al.Dosimetric and radiobiological impact of dose fractionation on respiratory mo- tion induced IMRT delivery errors: a volumetric dose measurement study[].Medical Physics.2006
  • 4Shirato H,Suzuki K,Sharp G,et al.Speed and amplitude of lung tumor motion precisely detected in four-dimen- sional setup and in real-time tumor-tracking radiotherapy[].International Journal of Radiation Oncology Biology Physics.2006
  • 5Underberg RWM,Lagerwaard FJ,Cuijpers JP,et al.4-dimensional CT scans for treatment planning in ster- eotactic radiotherapy for stage I lung cancer[].International Journal of Radiation Oncology Biology Physics.2004
  • 6Rietzel E,Chen GT,Choi NC,et al.Four-dimensional image-based treatment planning: target volume segmen- tation and dose calculation in the presence of respiratory motion[].IntJ RadiatOncol Biol Phys.2005
  • 7Rietzel E,Liu AK,Doppke KP,et al.Design of 4D treatment planning target volumes[].International Journal of Radiation Oncology Biology Physics.2006
  • 8Giraud P,Yorke E,Jiang S,et al.Reduction of organ motion effects in IMRT and conformal 3D radiation delivery by using gating and tracking techniques[].Cancer Radiotherapie.2006
  • 9LowDA,Nystrom M,Kalinin E,et al.Amethod for the reconstruction of four-dimensional synchronized CTscans acquired during free breathing[].Medical Physics.2003
  • 10Rietzel E,Pan T,Chen GT.Four-dimensional computed tomography: image formation and clinical protocol[].Medical Physics.2005

共引文献21

同被引文献3

  • 1Weiss E, Wijesooriya K, Dill SV, et al. Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D - CY [ J ]. Int J Radiat Oncol Biol Phys. 21~, 67 (1) : 296 - 307.
  • 2Stefan Klein, Marius Staring. Elastix manual v4. 4 [ EB/ PDF ] http: //elastix. isi. uu. nl/download, php, 2010, 11.
  • 3张书旭,周凌宏,杨俊,徐海荣,林生趣,余辉,王诗琴.基于4D-CT研究随呼吸运动靶区的剂量分布规律[J].中国医学物理学杂志,2010,27(3):1825-1828. 被引量:11

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;