摘要 目前3T磁共振设备的装机数量越来越多,随着场强的提高,不仅可以改善图像质量,同时也会带来一系列的伪影问题。这些伪影可能是由于高场本身的物理限度或者序列没有进行充分的优化所致。本文对3T磁共振设备的主要伪影问题进行分析,设法消除或将它们减小到最小程度,充分发挥3T磁共振设备的优势。 MRI systems at a field-strength of 3 T has been used more and more frequently in recent years.The high-field systems,not only can benefit the imaging quality,but also can cause some artifacts.These artifacts are caused either by physical limitations related to the high-field strength or by protocols that are not yet fully optimized for the high-fi eld strength.The most common artifacts will be analyzed in this paper,in order to mitigate or avoid them and take best advantage of high-field 3 T system.
作者 尹建忠
出处 《磁共振成像》 CAS 2010年第4期291-294,共4页 Chinese Journal of Magnetic Resonance Imaging
关键词 磁共振成像 高场 伪影 Magnetic resonance imaging High field Artifacts
  • 相关文献

参考文献15

  • 1Nakada T. Clinical experience on 3.0 T systems in Niigata, 1996 to 2002. Invest Radiol, 2003, 38(7): 377-384.
  • 2Nael K, Fenchel MC, Kramer U, et al. Whole-body contrast-enhanced magnetic resonance angiography: new advances at 3.0 T. Top Magn Reson Imaging, 2007, 18(2): 127-134.
  • 3Nakada T. Clinical application of high and ultra high-field MRI. Brain & Development, 2007, 29(6): 325-335.
  • 4Yablonskiy DA, Ha-acke EM. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn Reson Med, 1994, 32(6): 749-763.
  • 5Bemstein MA, Huston III J, Ward HA. Imaging artifacts at 3.0 T. J Magn Reson Imaging, 2006, 24(4): 735-746.
  • 6Merkle EM, Dale BM, Thomas J, et al. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 T. Eur Radiol, 2006, 16(10): 2309-2316.
  • 7Graf H, Lauer UA, Berger A, et al. RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study. Magn Reson Imaging, 2005, 23(3): 493-499.
  • 8Wieben O, Francois C, Reeder SB. Cardiac MRI of ischemic heart disease at 3 T: potentials and challenges. Eur J Radiol, 2008, 65(1): 15-28.
  • 9Deshpande VS, Shea SM, Li D. Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency. Magn Reson Med, 2003, 49(5): 803-809.
  • 10Merkle EM, Dale BM. Abdominal MRI at 3.0 T: the basics revisited. AJR Am J Roentgenol, 2006, 186(6): 1524-1532.

同被引文献143

引证文献16

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部