本文利用变压器本身的负序损耗功率,计算运行中负序损耗功率增加量的相对比率,在变压器故障诊断中引入一种新的特征判据,即负序损耗比率。通过理论的推导证明了本方法应用变压器故障诊断的合理性,最后通过实例说明本方法是切实可行的。
With the own losses of negative sequence power of transformers,this paper introduces a new characteristics of transformer fault diagnosis based on the relative ratio losses of the negative sequence power. Through theoretical study,it is demonstrated that the application of this method to transformer fault diagnosis is reasonable and feasible through examples.
关键词
电力变压器
故障诊断
损耗比率
负序功率
power transformer
fault diagnosis
relative looses
negative sequence power