期刊文献+

汽轮机停机后高压内下缸内壁温度急剧下降的原因分析及防范措施

The Cause Analysis and Preventive Measures of Temperature Drop of Inside Wall of High Pressure down Cylinder in Turbine after Turbine Stop
下载PDF
导出
摘要 针对云浮发电厂#2机组停机后汽轮机高压内下缸内壁温度急剧下降的现象,详细分析了造成此现象的原因,并采取了相应的防范措施,使高压内缸上、下缸温差控制在标准范围内,保证了汽轮机的安全稳定运行。 For an phenomenon that the temperature of inside wall of high pressure down cylinder in turbine dropped sharply after the Units have been stop of Yunfu Power station # 2, this paper analyzed the reason of this cause in detail, and have taken the corresponsive measures to control the temperature gap between the up cylinder and down cylinder of high pressure in standard scope, which ensured the safety and stable operation of turbine.
作者 梁权志
出处 《自动化应用》 2010年第8期72-73,共2页 Automation Application
关键词 汽轮机 高压内缸 缸温差 原因分析 热应力 turbine high pressure inner cylinder cylinder temperature difference cause analysis thermal stress
  • 相关文献

参考文献4

  • 1龚德君,等.汽轮机运行技术问答[M].北京:中国电力出版社,1997.
  • 2吴季兰.汽轮机设备及系统/300Mw火力发电机组丛书[M].北京:中国电力出版祉,2005.
  • 3山东电力集团公司.汽轮机运行与检修专业-汽轮机辅机检修工[M].北京:中国电力出版社,2005.
  • 4孙为民;等.电厂汽轮机[M].北京:中国电力出版社,2001.

相关作者