摘要 采用电容层析成像技术直接对稀疏气力输送的固体浓度进行测量是困难的。为克服电容传感器敏感场的不均匀性对成像造成的影响,实验系统中装置了一旋流浓缩装置,传感器电极布置在浓缩器直管上,对常温下稀疏气力输送的固体浓度进行了测试研究。通过对截面积体积分数分布、平均值以及浓波动特性的分析证明这种测试方法是可行的。通过调节浓缩器顶部的抽吸风量对断面径向浓度分布及平均体积分数进行分析研究,研究结果表明少量的抽吸会对成像有益,但抽吸量太大会扰乱流场而与引入旋流浓缩装置的目的相违背。 It is difficult to measure the concentration of solids in subtle gas-solids flow directly using electrical capacitance tomography (ECT).A cyclone is employed in the experimental system where the sensors are placed in order to compensate the inhomogeneity of the sensor sensitivity.Experimental studies are carried out on the subtle mass flow measurement in a pneumatic conveying pipeline.The distribution of volume concentration in radial direction,the average volume concentration and the fluctuating characteristics are analyzed.The experimental results show this method is workable by means of the online metering system.The distribution of solids in the cross section and the diversification of volume concentration in radial direction are analyzed by changing the suction amount in the top of the cyclone.The experimental results show that a little amount is favorable to the tompography,but too much amount will disturb the cyclone field.
出处 《锅炉技术》 北大核心 2010年第4期6-9,共4页 Boiler Technology
基金 国家自然科学基金(60672151 50736002)
关键词 电容层析成像 浓度测量 体积浓度 旋流浓缩 electrical capacitance tomography concentration measurement volume concentration cyclone condensation
  • 相关文献

参考文献12

  • 1Chunsheng Yan,Jing Zhong,Yanbiao Liao,et al.Design of applied optical fiber process tomography system[J].Sensors and Actuators B:Chemical,2005,104(2):324-331.
  • 2Yingna Zheng,Qiang Liu,Yang Li,et al.Investigation on concentration distribution and mass flow rate measurement for gravity chute conveyor by optical tomography system[J].Measurement,2006,39(7):643-654.
  • 3Ellis N,Briens L A,Grace J R,et al.Characterization of dynamic behavior in gas-solid turbulent fluidized bed using chaos and wavelet analyses[J].Chemical Engineering Journal,2003,96(2):105-116.
  • 4Ying Zheng,Qikai Zhang.Simultaneous measurement of gas and solid holdups in multiphase systems using ultrasonic technique[J].Chemical Engineering Science,2004,59(17):3505-3514.
  • 5Hosseini S A,Shamsai A,Ataie-Ashtiani B.Synchronous measurements of the velocity and concentration in low density turbidity currents using an Acoustic Doppler Velocimeter[J].Flow Measurement and Instrumentation,2006,17(1):59-68.
  • 6Yan Y,Byrne B,Coulthard J.Radiation attenuation of pulverized fuel in pneumatic conveying systems[J].Trans.Inst.Meas.Control,1993,15(2):98-103.
  • 7Beck M S,Williams R A.Process tomography:A European innovation and its applications[J].Meas.Sci.and Technol.,1996,7(3):215-224.
  • 8Dyakowski T,Luke S P,Ostrowski K L.Application of capacitance tomography to gas-solid flows[J].Chem.Eng.Sci.,1997,52(13):2099-2105.
  • 9Wang S,Dyakowski T,Beck M S.An application of electrical capacitance tomography to measure gas-solid motion in fluidized bed[A].Heat-transfer[C].AICHE Symposium Series,Houston,1996:156-159.
  • 10Yang W Q,Liu S.Electrical capacitance tomography with square sensor[J].Electronics Letters,1999,35(4):295-296.

同被引文献14

  • 1王化祥,朱学明,张立峰.用于电容层析成像技术的共轭梯度算法[J].天津大学学报(自然科学与工程技术版),2005,38(1):1-4. 被引量:38
  • 2崔自强.双模态电学层析成像技术研究[D].天津:天津大学,2009.
  • 3BOLTON G T, KORCHINSKY W J, WATERFALL R C.Calibration of capacitance tomography system for liquid-liquid dispersions [JJ.Meas Sci Technol, 1998,9( 11): 1797-1800.
  • 4Complete 12-Bit, 40 MSPS Monolithic A/D Converter [S].1999.
  • 5吴建.基于FPGA的PCI数据采集卡的研究与开发[D].长沙:中南大学.2007.
  • 6YANG W Q.Hardware design of electrical capacitance tom-ography systems [J]. Measurement Science and Technology1996,7(3):225-232.
  • 7MARTIN M D,ORMAETXEA M,HARISMENDY I,et al. Cure Chemo- rheology of mixtures based on epoxy resins and ester cyanates. European Polymer Journal, 1999,35 ( 1 ) :57 - 68.
  • 8崔自强.双模态电学层析成像技术研究:[学位论文].天津:天津大学,2009.
  • 9BOLTON G T,KORCHINSKY W J,WATERFALL R C. Calibration of Capacitance Tomography System for Liquid - liquid Dispersions. Meas Sci Technol, 1998,9 ( 11 ) : 1797 - 1800.
  • 10Complete 12 -Bit,40 MSPS Monolithic A/D Converter. 1999.

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部