介绍了通过提出各种方案并最终确定最佳方案后,成功开发了酸性水氯离子含量测定的方法——分光光度法,该方法采用大倍数稀释水样的方法来排除干扰,操作简单快捷。实践证明:该方法非常适合分析酸性水氯离子含量,使得氯离子含量可测定率达到100%,解决了困扰多年公司酸性水氯离子无法测定的难题,同时也为同行解决类似问题开拓了思路。
By proposing and ultimately determining the best scheme was introduced,the analysis method of acidic water chlorine ions was determined etc.spectrophotometric.Proven:the method is a good ideal for analysis acidic water chlorine ions.The content of chlorine ions was caused observable fixed rate to achiveve 100%.The situation was solved that company was unable to analyze acidic water chlorine ions for many years, simultaneously also solved the similar problem for the colleague to develop the mentality.