期刊文献+

双源CT在儿童可疑气道异物诊断中的应用 被引量:4

Application value of dual-source CT in the diagnosis of suspicious airway foreign bodies in children
原文传递
导出
摘要 目的:探讨双源CT对于儿童可疑气道异物诊断的临床价值。方法:对22例怀疑气道异物的儿童行双源CT扫描,扫描数据经后处理重建,包括多平面重建、最小密度投影、仿真内镜和容积再现,结果与气管镜探查术中所见相对照。结果:数据后处理结果清晰显示异物的部位、大小、形态及伴随征象,发现异物影20例,术中证实异物19例,1例为黏脓性分泌物,诊断符合率为95%。结论:双源CT扫描及数据后处理对气道异物的显示率高,定位准确,对可疑气道异物的诊断有重要临床价值。 Objective:To evaluate the clinical value of dual-source computer tomography in the diagnosis of suspicious airway foreign bodies in children.Method:Twenty-two children of suspicious airway foreign bodies were examined by DSCT. The original scanning data were reconstructed with MPR,MinP,CTVE and VR. The results were compared with surgical findings.Result:The position,size,shape and accompanying signs of foreign bodies were clearly demonstrated by DSCT.Twenty cases were diagnosed as foreign bodies in the airway by DSCT. Nineteen cases were confirmed as foreign bodies.Purulent discharge was found by bronchoscopy in 1 case. The rate of conformed diagnosis was 95%.Conclusion:DSCT can demonstrate the foreign body clearly and play an important role in the diagnosis of suspicious airway foreign body in children.
出处 《临床耳鼻咽喉头颈外科杂志》 CAS CSCD 北大核心 2010年第15期700-702,共3页 Journal of Clinical Otorhinolaryngology Head And Neck Surgery
关键词 气道异物 双源CT 气管镜探查术 儿童 airway foreign body dual-source computer tomography bronchoscopy children
  • 相关文献

参考文献6

  • 1COSANO P A,MUNOZ C L,COSAN0 POVEDANO F J,et al.Endoscopic treatment of central airway stenosis:five years'experience[J].Arch Bronconeumol,2005,41:322-327.
  • 2CIFTCIAO,BINGOLK M,SENOCAK ME,et al.Bronchoscopy for evaluation of foreign body aspiration in children[J].J Pediatr Surg,2003,38:1170-1176.
  • 3KOSUCU P,AHMETOGLU A,KORAMAZ I,et al.Low-dose MIX;T and virtual bronchoscopy in pediatric patients with foreign body aspiration[J].AJR Am J Roentgenol,2004,183:1771-1777.
  • 4APPLEGATE K E,DARDINGER J T,LIEBER M L,et al.Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies[J].Pediatr Radiol,2001,31:836-840.
  • 5苗英章,步桂清,张秀者,荣宏,张勋.气管支气管异物X线表现与临床分析[J].河北医科大学学报,2004,25(1):39-40. 被引量:29
  • 6LEE K S,YOON J H,KlM T K,et al.Evaluation of tracheobronchial disease with helical CT with multiplanar and three-dimensional reconstruction:correlation with bronchoscopy[J].Radiographics,1997,17:555-567.

二级参考文献5

  • 1Wunsch R, Wunsch C, Darge K. Foreign body aspiration[J]. Radiology,1999,39(6):467-471.
  • 2Applegate KE, Daedinger JT, Lieber ML, et al. Spiral CT scanning technigue in the detection of aspiration of LEGO foreign bodies[J]. Pediatr Radiol,2001,31(12):836-840.
  • 3Mu LC, Sun DQ, He P. Radiological diagnosis of aspirated foreign bodies in children: review of 343 cases[J]. J Laryngol Otol,1990,104(10):778-782.
  • 4Silva AB, Muntz HR, Clary R. Utility of conventional radiography in the diagnosis and management of pediatric airway foreign bodies[J]. Ann Otol Rhinol Laryngol,1998,107(10 Pt1):834-838.
  • 5Losek JD. Diagnostic difficulties of foreign body aspiration in children[J]. Am J Emerg Med,1990,8(4): 348-350.

共引文献28

同被引文献37

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部