板坯输送液压系统在调试过程中,回转部分、水平移送部分、升降部分各自出现了一些问题,分别对其进行详细分析,并提出改进措施。实际应用表明,改进后的系统解决了原系统存在的问题,连续运行情况良好。
During the commissioning of the hydraulic system for slab conveying,some problems occur to the rotating part,the horizontal transfer part and lifting part respectively,and then detailed analysis is performed for the problems with also improvement measures proposed. The application shows that improved system solves the problems of the original system,and the continuous operation is sound.
出处
《起重运输机械》
2010年第8期86-89,共4页
Hoisting and Conveying Machinery
基金
湖北省自然科学基金项目(2007ABA271)
关键词
板坯输送
液压系统
故障分析
改进
slab conveying
hydraulic system
failure analysis