期刊文献+

一种人血浆中多氯联苯测定方法的建立 被引量:1

Research on assaying of polychlorinated biphenyls (PCBs) in human plasma
下载PDF
导出
摘要 建立人血浆中多氯联苯(PCBs)的检测方法,为流行病学调查提供灵敏、可靠的技术手段。利用5%Na2SO4、乙腈和1-丙醇/水(85∶15)超声提取人血浆中的PCBs,固相萃取后,采用气相色谱-电子捕获器联用的方法(GC-ECD)测定血浆中PCBs的含量。7种PCBs在1~50ng/mL范围内线性良好(R>0.9998),在5、20ng/mL加标水平下,7种PCBs回收率在86.50%~120.00%之间,精密度在1.76%~8.13%范围内。PCBs的检出限为0.04~0.08ng/mL。 This paper aims to establish a sensitive and reliable analytical method for analyzing polychlorinated biphenyls(PCBs)in human plasma.PCBs in human plasma were extracted ultrasonically with 5% Na2SO4,acetonitrile and 1-propanol/water(85∶15,V∶V),cleaned up by solid phase extraction with a C18 cartridge,concentrated and determined by gas chromatography with ECD(election capture detector).The calibration curves of PCBs were linear(R0.999 8)at a concentration ranging from 1 ng/mL to 50 ng/mL.The recoveries of the PCBs for human plasma identified at the 5 ng/mL and 20 ng/mL levels were between 86.50% and 120.00%.The analytical precisions within a day were 1.76%~8.13%.The limits for detection of PCBs were in the range of 0.04~0.08 ng/mL.
出处 《化学试剂》 CAS CSCD 北大核心 2010年第8期707-710,共4页 Chemical Reagents
基金 上海市科委基金资助项目(06DZ22024) 上海市环境与儿童健康重点实验室项目(08DZ2271200)
关键词 多氯联苯 固相萃取 气相色谱 人血浆 polychlorinated biphenyls(PCBs) solid phase extraction gas chromatography human plasma
  • 相关文献

参考文献13

  • 1Stockholm convention on persistent organic pollutants [ EB/OL]. http://www, pops. int/documents/convtext/ Context-en. pdf.
  • 2CRUZ S, LINO C,SILVEIRA M I. Evaluation of organochlorine pesticide residues in human serum from an urban and two rural populations in Portugal[ J]. Sci. Total Environ. , 2003,317 ( 1/3 ) : 23 -35.
  • 3AXMON A,RYLANDER L,STROMBERG U, et al. Polychlorinated biphenyls in serum and time to pregnancy [ J ]. Environ. Res. , 2004,96 ( 2 ) : 186-195.
  • 4BATES M N, BUCKLAND S J, GARRETT N, et al. Persistent organochlorines in the serum of the non-occupationally exposed New Zealand population [ J ]. Chemo- sphere, 2004,54 ( 10 ) : 1431-1443.
  • 5FERNANDO G, RAUL L, ARSENIO E. High throughput method for the determination of organochlorine pesticides and polychlorinated biphenyls in human serum [ J ]. J. Chromatogr. B ,2007,852 ( 1/2 ) : 15 -21.
  • 6FRANKEN J J,LUYTEN B J M. Comparison of dieldrin, lindane, and DDT extractions from serum, andgas liquid chromatography using glass capillary columns [ J ]. JAOAC,1976,59(6) :1 279-1 285.
  • 7NAJAM A R,KORVER M P,WILLIAMS C C,et al. A- nalysis of a mixture of polychlorinated biphenyls and chlorinated pesticides in human serum by column fractionation and dual-column capillary gas chromatography with electron capture detection [ J ]. JAOAC, 1999, 82 (1) :177-185.
  • 8ROGERS E, PETREAS M, PARK J S, et al. Evaluation of four capillary columns for the analysis of organochlorine pesticides,polychlorinated biphenyls, and polybrominated diphenyl ethers in human serum for epidemiologic studies [ J ]. J. Chromatogr. B, 2004,813 ( 1/2 ) : 269-285.
  • 9GOMARA B,RAMOS L,GONZA LEZ M J. Determination of polychlorinated biphenyls in small-size serum sam- ples by solid-phase extraction followed by gas chromatog- raphy with micro-electron-capture detection [ J ]. J. Chromatogr. B, 2002,766 ( 2 ) : 279-287.
  • 10CONKA K,DROBN'A B,KOCAN A,et al. Simple solid-phase extraction method for determination of polychlori-hated biphenyls and selected organochlorine pesticides in human serum [ J ]. J. Chromatogr. A, 2005,1 084 ( 1/ 2) :33-38.

同被引文献37

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部