期刊文献+

X线立体定位引导真空负压旋切活检在诊断0期乳腺癌的应用价值 被引量:4

The benefits of X-ray guided vacuum-assisted breast biopsy in diagnosis of stage 0 breast cancer
原文传递
导出
摘要 目的探讨X线立体定位引导真空负压旋切活检技术在临床触诊和B超检查均为阴性乳腺微小病灶中诊断0期乳腺癌方面的价值。方法本院于2007年10月~2009年5月用数字化俯卧式穿刺活检定位系统引导真空负压旋切活检系统对113例B超检查为阴性临床不可触及的X线下可疑病灶(BIRADS评级为4级)进行微创切取活检。结果手术成功率100%。113例病例中共发现18例乳腺癌,其中乳腺导管内癌12例,导管内癌并微浸润(浸润突破基底膜小于2mm)4例,浸润性导管癌1例,浸润性小叶癌1例。乳腺癌术后病理分期0期12例,Ⅰ期6例。无严重出血等并发症。结论 X线立体定位引导真空负压旋切活检临床触诊和B超检查均为阴性的X线下乳腺微小病灶,对诊断0期乳腺癌有较高的价值。 Objective To assess the benefits of stereotactic-guided vacuum assisted breast biopsy in diagnosing stage 0breast cancer in patients with breast lesions that are impalpable and can not be detected by ultrasound.Methods From October 2007to May 2009,X-ray guided vacuum assisted breast biopsy was performed for 113patients with dubious breast lesions that were impalpable and ultrasound-positive and assigned BI-RADS(Breast Imaging Reporting and Data System)category 4by X-ray mammography in our hospital.Results The operation success rate was 100%.Among the 113cases,18were detected with breast cancer,of them,12cases had intraductal carcinoma,4had microinvasive ductal carcinoma,with less than 2mm basilar membrane invaded,1had invasive ductal carcinoma,and 1had invasive lobular carcinoma.Pathological staging showed stage 0in 12cases,stage I in 6cases.No serious hemorrhage or other complications occurred.Conclusions X-ray guided vacuum assisted breast biopsy is of clinical value in diagnosing stage 0breast cancer in patients with non-palpable,ultrasound-positive and dubious mammography breast lesions.
出处 《中华乳腺病杂志(电子版)》 CAS 2010年第4期20-22,共3页 Chinese Journal of Breast Disease(Electronic Edition)
基金 深圳市科技局项目(200703268)
关键词 立体定位技术 活组织检查 针吸 乳腺肿瘤 早期诊断 Stereotactic techniques Biopsies Breast neoplasms Early diagnosis
  • 相关文献

参考文献8

  • 1Hanna WC,Demyttenaere SV,Ferri LE,et al.The use of stereotactic excisional biopsy in the management of invasive breast cancer.World J Surg,2005,29:1490-1494.
  • 2Smith B.Physician predictors of mammographic accuracy.J Natl Cancer Inst,2005,97:358.
  • 3Jackman RJ,Rodriguez-Soto J.Breast microcalcifications:retrieval failure at prone stereotactic core and vacuum breast biopsy frequency,causes,and outcome.Radiology,2006,239:61-70.
  • 4Warren R,Hayes C,Pointon L.A test of performance of breast MRI interpretation in a multicentre screening study.Magn Reson Imaging,2006,24:917-929.
  • 5倪耀忠,罗定存,李霄阳,周宏,叶英海,周海滨,王岚.乳腺X线市体定位活检在临床不可触及的乳腺病变诊断中的应用[J].温州医学院学报,2006,36(1):56-57. 被引量:3
  • 6朱少萍,张妙芳,江家祥,李洁芳.全数字化乳腺摄影对乳腺癌的诊断价值[J].实用医学影像杂志,2006,7(2):120-122. 被引量:11
  • 7傅建民.X线立体定位下核芯针穿刺活检诊断早期乳腺癌[J].现代肿瘤医学,2007,15(4):570-571. 被引量:9
  • 8Uematsu T,Kasami M.The use of positive core wash cytology to estimate potential risk of needle tract seeding of breast cancer:directional vacuum-assisted biopsy versus automated core needle biopsy.Breast Cancer,2010,17:61-67.

二级参考文献27

  • 1徐景伟,聂建国,李晓英,关文曾.X线摄片计算机辅助定位穿刺活检对早期乳腺癌的诊断价值[J].肿瘤防治杂志,2005,12(5):381-382. 被引量:2
  • 2Sickles Ea.Quality Assurance:How to audit your own mammography practice[J].Radioi Clin North Am,1992,30(1):265,275.
  • 3Velanovich V,Lewis FR Jr,Nathanson SD,et al.Comparison of mammographically guided breast biopsy techniques[J].Ann Surg,1999,229(5):625-630.
  • 4Verkooijen HM,Peeters PH,Pijnappel RM,et al.Diagnostic accuracy of needle-localized open breast biopsy for impalpable breast disease[J].Br J Surg,2000,87(3):344-347.
  • 5Skaane P,Bailey guier C,Diekmann F,et al.Breast lesion detection and classification:comparison of screen-film mammography and full -field digital mammograplvy with soft-copy readingobserver performance study[J].Radiology,2005,237 (1):37 -44.
  • 6Fischmann A,Siegmann KC,Wersebe A,ea al.Comparison of full-field digital mammography and film-screen mammography:image quality and lesion detection[J].Br J Radiol,2005,78 (928):312-315.
  • 7胡永升.现代乳腺影像诊断学[M].北京:科学出版社,2002:66
  • 8Obenauer S,Hermann KP,Schom C,et al.Full-field digital mammography:dose-dependent detectability of breast lesions and microcalcinosis[J].Rofo Fortschr Geb Rintgenstr NeuenBildgeb Verfahr,2000,172 (12):1052-1056.
  • 9Fischer U,Baum F,Obenauer S,et al.Comparative study in patients with microcalcifications:full-field digital mammography vs screen-film mammography[J].Eur Radiol,2002,12(11):2679-2683.
  • 10Sickles EA.Quality Assurance:how to audit your own mammogaphy pracice[J].Radiol Clin North Am,1992,30:187 ~ 210.

共引文献20

同被引文献53

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部