超临界直流炉首次检修化学检查共性问题及对策 被引量:2

Discussion on Chemistry Check-up of Supercritical Once-through Boiler
原文传递
导出
摘要 总结了河南省8台采用给水还原性全挥发处理方式的600 MW超临界直流炉机组首次检修化学检查中发现的共性问题:水冷壁、省煤器的结垢速率较高;汽轮机叶片积盐速率较高,沉积物成分复杂;机组停运揭缸后低压缸叶片有锈蚀。针对以上问题,分析了其原因,并提出了解决问题的建议。 The chemistry check-up was carried out in the first maintenance of eight AVT treatment supercritical once-through boiler 600 MW units in Henan,and some common problems were found,including high scaling rate of the water-cooled wall and coal economizer,high salt deposition rate on the turbine blades,complex composition of deposits,and blade crusting corrosion of low-pressure cylinder.The causes for the problems are analyzed and relevant countermeasures are proposed.
出处 《电力建设》 2010年第8期71-74,共4页 Electric Power Construction
关键词 超临界机组 直流炉 给水处理 结垢 积盐 腐蚀 supercritical unit once-through boiler feed water treatment scale formation salt deposition corrosion
  • 相关文献

参考文献15

二级参考文献4

  • 1GB12145-1999.火力发电机组及蒸汽动力设备水汽质量标准[S].[S].,..
  • 23Cycle Chemistry Guidelines for Fossil Plants: All-Volatile Treatment[R]EPRI TR- 105041.
  • 3Cycle Chemistry Guidelines for Fossil Plants:Oxygenated Treatment[R]EPRI TR- 102285.
  • 4Selection and Optimization of Boiler Water and Feedwater Treatments for Fossil Plants [R] .EPRI TR- 105040.