期刊文献+

Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots 被引量:1

Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots
下载PDF
导出
摘要 A novel third-generation hydrogen peroxide(H2O2) biosensor(Hb/CdS/MWNTs/GCE) was fabricated through hemoglobin(Hb) adsorbed onto the mercaptoacetic acid modified CdS QDs/carboxyl multiwall carbon nanotubes'(MWNTs) films. Cyclic voltammogram of Hb/CdS/MWNTs/GCE showed a pair of well-defined and quasi-reversible redox peaks with a formal potential(E^0) of-0.230 V(vs. Ag/AgCl) in 0.1 mol/L pH=8.0 phosphate buffer solution(PBS), which was the characteristic of the Hb heme Fe(Ⅲ)/Fe(Ⅱ) redox couple. The biosensor shows an excellent electrocatalytic activity to the reduction of H2O2. The response time of the designed biosensor to H202 at a potential of-0.30 V was less than 2 s and linear relationships were obtained in the concentration ranges of 2.0×10^-6-2.7×10^-3 mol/L and 2.7×10^-3-7.7×10^-3 mol/L with a detection limit of 3.0×10^-7 mol/L(S/N=3). The apparent Michaelis-Menten constant Km was estimated to be 1.324 mmol/L that illustrated the excellent biological activity of the fixed Hb. A novel third-generation hydrogen peroxide(H2O2) biosensor(Hb/CdS/MWNTs/GCE) was fabricated through hemoglobin(Hb) adsorbed onto the mercaptoacetic acid modified CdS QDs/carboxyl multiwall carbon nanotubes'(MWNTs) films. Cyclic voltammogram of Hb/CdS/MWNTs/GCE showed a pair of well-defined and quasi-reversible redox peaks with a formal potential(E^0) of-0.230 V(vs. Ag/AgCl) in 0.1 mol/L pH=8.0 phosphate buffer solution(PBS), which was the characteristic of the Hb heme Fe(Ⅲ)/Fe(Ⅱ) redox couple. The biosensor shows an excellent electrocatalytic activity to the reduction of H2O2. The response time of the designed biosensor to H202 at a potential of-0.30 V was less than 2 s and linear relationships were obtained in the concentration ranges of 2.0×10^-6-2.7×10^-3 mol/L and 2.7×10^-3-7.7×10^-3 mol/L with a detection limit of 3.0×10^-7 mol/L(S/N=3). The apparent Michaelis-Menten constant Km was estimated to be 1.324 mmol/L that illustrated the excellent biological activity of the fixed Hb.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第4期541-545,共5页 高等学校化学研究(英文版)
基金 Supported by the Natural Science Foundation of Guangxi Province,China(Nos.0639025 and 0991084) the Support Program for 100 Young and Middle-aged Disciplinary Leaders in Higher Education Institutions of Guangxi Province,China(No. RC20060703005) the Key Laboratory of Development and Application of Forest Chemicals of Guangxi Province,China (No.GXFC08-06) the Education Department of Guangxi Province,China(No.200807MS074) the Innovation Project of Guangxi University fot Nationalities,China(No.gxun-chx2009081)
关键词 HEMOGLOBIN CdS quantum dot Multi-wall carbon nanotube BIOSENSOR Direct electrochemistry Hemoglobin CdS quantum dot Multi-wall carbon nanotube Biosensor Direct electrochemistry
  • 相关文献

参考文献28

  • 1Li Y., Umasankar Y., Chen S. M., Anal. Biochem., 2009, 388, 288.
  • 2Tan X. C., Mai Z. B., Wei D. P., Deng G. H., Huang Z. Y., Cai P. X., Chin. J. Anal. Chem., 2007, 35, 495.
  • 3Zhou H., Sun C. Q., Chem. J. Chinese Universities, 2008, 29(11), 2159.
  • 4Lin J. H., He C. Y., Zhao Y., Zhang S. S., Sens. Actuators, B, 2009, 137, 768.
  • 5Zhao H. Y., Zheng W., Meng Z. X., Zhou H., M., Xu X. X., Li Z., Zheng Y. F., Biosens. Bioelectron., 2009, 24, 2352.
  • 6Alivisatos A. P., Science, 1996, 271,933.
  • 7Bruchez M. Jr., Moronne M., Gin P., Weiss S., Paul Alivisatos A., Science, 1998, 281, 2013.
  • 8Jin W. J., Costa-Femandez J. M., Pereiro R., Sanz-Medel A., Anal. Chim. Acta, 2004, 522, 1.
  • 9Song J., Fan J., Song D. Q., Bi L. R., Zhou G. Y., Zhang H., Wei J. Y., Yang B., Chem. J. Chinese Universities, 2009, 30(10), 1940.
  • 10Huang Y. X., Zhang W. J., Xiao H., Li G. X., Biosens. Bioelectron., 2005, 21, 817.

同被引文献28