期刊文献+

炼油含酚废水生物脱酚的控制条件探讨 被引量:1

Discussion on Control Factors of Phenolic Wastewater Treatment by Biological Method
下载PDF
导出
摘要 采用生物塔对炼油含酚废水进行脱酚处理,对生物脱酚的控制条件如水力停留时间、气水比、生物脱酚温度、pH值和生物塔反冲洗周期进行了探讨。研究结果是对于酚浓度低于200 mg.L-1的炼油含酚废水,当HRT为3.0h、气水比为8.0、温度为25~40℃、pH值为6.8~8.0和生物塔反冲洗周期为2~3d,则酚去除率可达到99%以上,出水酚浓度低于0.5mg·L-1,脱酚效果理想。 When biological-tower was used in treatment of the refinery sewage containing phenol,the control factors such as HRT,air/water ratio,temperature,pH and backwash frequency were discussed.The satisfactory results were obtained: when the phenol content of influent was below 200mg/L,HRT was 3.0h,air/water ratio was 8.0,temperature was 25~40℃,pH was 6.8~8.0 and backwash frequency was 2~3d,the removal efficiency of phenol was greater than 99% and the phenol content of effluent was below 0.5mg/L.
作者 李锋
出处 《化工技术与开发》 CAS 2010年第8期53-54,58,共3页 Technology & Development of Chemical Industry
关键词 炼油废水 生物塔 控制条件 refinery sewage phenol biological-tower control factor
  • 相关文献

参考文献4

共引文献135

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...