介绍非晶合金干式变压器的原理和特点,分析其节能的经济性,提出了采用非晶合金变压器降低地铁配电变压器空载损耗水平的技术方案。结合地铁系统的特点,论证了非晶合金干式变压器在地铁中推广应用的可行性。
The energy-saving principle and characteristics of amorphous alloy transformer are introduced in this paper. Then, the scheme that using amorphous alloy transformer to reduce the no-load loss of distribution transformer in metro Combined with the characteristics of metro system, the feasibility of applying and popularizing amorphous alloy dry-type transformer is verified.
出处
《电气化铁道》
2010年第4期39-41,46,共4页
Electric Railway
关键词
非晶合金
干式变压器
地铁
空载损耗
节能
amorphous alloy
dry-type transformer
metro
no-load loss
energy-saving