摘要 冷却塔是集中空调系统的重要组成部分,开式逆流冷却塔在大型公共建筑空调系统中应用广泛,但实际运行过程中却普遍存在效率偏低的问题。以制冷机和冷却塔构成的系统为研究目标,提出了以制冷机节能为核心的优化思路。建立了半经验理论模型进行模拟计算,并在实际建筑中进行了改造测试,总结分析得到了冷却塔风机联合变频调节和高低风速调节的控制方法。 Cooling tower is one of the most important components of central air conditioning system.Counter-flow wet-cooling towers are commonly used in large public buildings while with lower efficiency in most buildings.Taking the system composed of chillers and cooling towers as an object,puts forward the optimization way based on an overall consideration of chiller energy efficiency.Concludes a simple control strategy combined with variable frequency and high/low speed regulation for the fans of cooling tower by establishing a semi-empirical theoretical model and the renovation testing in an actual building.
出处 《暖通空调》 北大核心 2010年第8期45-50,共6页 Heating Ventilating & Air Conditioning
关键词 冷却塔 冷源 优化 模拟 节能 cooling tower cold source optimization simulation energy efficiency
  • 相关文献

参考文献7

二级参考文献13

  • 1[1]Braun JE and Diderrich GT.Near-optimal Control of Cooling Towers for Chilled-water Systems[J].ASHRAE Transactions,1990,96(2):806-813.
  • 2[2]Crowther H and Furlong J.Optimizing Chillers & Towers[J].ASHRAE Journal,2004,46(7):34-44.
  • 3[3]Chan W.Y.Optimizing Chiller Plant Control Lclgic[J].ASHRAE Journal,2006,48(7):38-42.
  • 4[4]Wang SW,Xu XH and Ma ZJ.Report on the Energy Performance Evaluation of International Commerce Center (ICC)[R].Report submitted to Sun Hung Kai Properties Limited(SHK),May,2006.
  • 5[5]Yao Y,Lian ZW and Hou ZJ et al.Optimal Operation of A Large Cooling System Based on Empirical Model[J].Applied Thermal Engineering,2004,24(16):2303-2321.
  • 6[6]Sun J and Reddy A.Optimal Control of Building HVAC & R Systems Using Complete Simulation-based Sequential Quadratic Programming (CSB-SQP)[J].Building and Environment,2005,40(5):657-669.
  • 7[7]Hackner RJ,Mitchell JW and Bechman WA.HVAC System Dynamics and Energy Use in Buildings-part[J].ASHRAE Transactions,1985,91(1):781-795.
  • 8[8]Lau AS.Development of Computerized Control Strategies for A Large Chilled Water Plant.ASHRAE Transactions,1985,91(1):766-780.
  • 9[9]Braun JE.Reducing Energy Costs and Peak Electrical Demand through Optimal Control of Building Thermal Storage[J].ASHRAE Transactions,1990,96(2):876-888.
  • 10Merkel F. Verdunstungskuhlung. VDI Forschungsarbeiten, Berlin, 1925

共引文献19

同被引文献55

引证文献13

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部