摘要 本文建立了血清肌酸激酶BB同工酶(CK-BB)快速放射免疫测定(RIA)方法,灵敏度0.5ng/ml,测定范围0.5~100ng/ml,方法学鉴定符合RIA要求。本实验中正常组其值为1.3±1.8ng/ml。以CK-BB大于3.0ng/ml为阳性,急性心肌梗塞(AMI)组在心肌梗塞后8h男(n=22)、女(n=12)阳性率分别为86%和83%,24h均为100%。急性脑血管意外(CVA)组在脑血管意外后第1天男(n=24)、女(n=6)阳性率分别为8%和17%,第3天分别为79%和83%。方法特异性均为100%。 A quick radioimmunoassay for creatine kinase BB isoenzyme (OK-BB) is reported. The sensitivity was 0.5 ng/ml, and the range of measurements was 0.5-100ng/ml. The serum OK-BB levels in 83 normal controls were 1.3 - 0.8 ng/ml (x±SD). Values higher than 3.0ng/ml were regarded as positive. 8 hours after acute myocardial infarction, 86% were positive in males (n=22) and 83% in females(n=12). 24 hours after infarction, 100% were positive in both sexes. One the first day after cerebrovascular accidents, 8% of males (n=24) showed positive reactions and 17 % in females (n = 6). On the 3rd day positive results occurred in 79% of males and 83% of females. The specificity of this method was 100% in either group.
出处 《上海医科大学学报》 CSCD 1990年第1期5-9,共5页 Journal of Fudan University(Medical Science)
基金 国家教委博士点基金
关键词 肌酸激酶B 同功酶 放射免疫测定 creatine kinase iaoenzymes quick radioimmunoasay acute myocardial infarction cerebrovascnlar accident