期刊文献+

Difference-frequency ultrasound generation from microbubbles under dual-frequency excitation 被引量:1

Difference-frequency ultrasound generation from microbubbles under dual-frequency excitation
下载PDF
导出
摘要 The difference-frequency (DF) ultrasound generated by using parametric effect promises to improve detection depth owing to its low attenuation, which is beneficial for deep tissue imaging. With ultrasound contrast agents infusion, the harmonic components scattered from the microbubbles, including DF, can be generated due to the nonlinear vibration. A theoretical study on the DF generation from microbubbles under the dual-frequency excitation is proposed in formula based on the solution of the RPNNP equation. The optimisation of the DF generation is discussed associated with the applied acoustic pressure, frequency, and the microbubble size. Experiments are performed to validate the theoretical predictions by using a dual-frequency signal to excite microbubbles. Both the numerical and experimental results demonstrate that the optimised DF ultrasound can be achieved as the difference frequency is close to the resonance frequency of the microbubble and improve the contrast-to-tissue ratio in imaging. The difference-frequency (DF) ultrasound generated by using parametric effect promises to improve detection depth owing to its low attenuation, which is beneficial for deep tissue imaging. With ultrasound contrast agents infusion, the harmonic components scattered from the microbubbles, including DF, can be generated due to the nonlinear vibration. A theoretical study on the DF generation from microbubbles under the dual-frequency excitation is proposed in formula based on the solution of the RPNNP equation. The optimisation of the DF generation is discussed associated with the applied acoustic pressure, frequency, and the microbubble size. Experiments are performed to validate the theoretical predictions by using a dual-frequency signal to excite microbubbles. Both the numerical and experimental results demonstrate that the optimised DF ultrasound can be achieved as the difference frequency is close to the resonance frequency of the microbubble and improve the contrast-to-tissue ratio in imaging.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第9期437-442,共6页 中国物理B(英文版)
基金 supported by the National Natural Science Foundation of China (Grant Nos.10974098 and 10774071) the Natural Science Foundation of Jiangsu Province,China (Grant No.BK2009407) the Doctoral Foundation of Ministry of Education of China (Grant No.20093207120003) the National Basic Research Program of China (Grant No.2010CB732600)
关键词 difference-frequency MICROBUBBLE dual-frequency excitation parametric effect difference-frequency, microbubble, dual-frequency excitation, parametric effect
  • 相关文献

参考文献24

  • 1Wells P N T 2006 Phys. Med. Biol. 51 R83.
  • 2Westervelt P J 1975 J. Acoust. Soc. Am. 29 199.
  • 3Gong X F, Zhang D, Liu J H, Wang H L, Yan Y S and Xu X C 2004 J. Acoust. Soc. Am. 116 1819.
  • 4Chiou S Y, Forsberg F, Fox T B and Needleman L 2007 J. Ultrasound Med. 26 1557.
  • 5Fatemi M and Greenleaf J F 1998 Science 280 82.
  • 6Erpelding T N, Hollman K W and O'Donnell M 2005 IEEE Trans. Ultrason. Ferr. Freq. Contr. 52 971.
  • 7Wang H L, Zhu X F, Gong X F and Zhang D 2003 Chin. Sci. Bull. 48 2427.
  • 8Ophir J and Parker J P 1989 Ultrasound Med. Biol. 15 319.
  • 9de Jong N, Cornet R and Lancee C T 1994 Ultrasonics 32 447.
  • 10Gong Y J, Zhang D, Gong X F, Tan K B and Liu Z 2006 Chin. Phys. 15 1526.

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部