为解决连栋温室冬季能耗大、费用高的问题,进行了采用地中热交换系统部分代替燃煤的贮热加温试验。测定了空气和管道周围土壤贮、放热前后的温度等参数变化,系统在夜间加温能力可达加温热流量60W/m2,可有效保证夜间室内气温高于室外11℃以上。
In China, the cost of production in multispan greenhouse is very high for its
high energy consumption. It is necessary to develop the technology of energy saving for
multispan greenhouse production. The heating experiment using underground heat storage
system, replacing fuel to some extent, was carried out in a multispan greenhouse. It was
showed that the solar heat can be stored during the daytime by circulating the warm
greenhouse air through the pipes buried in the greenhouse soil, and the heat can be obtained
effectively from the soil through the pipes at night. During the daytime, the warm greenhouse air
was cooled down and decreased in temperature by 6 ̄8 and in enthalpy by 13 ̄20kJ/kg, after
flowed through the pipes and stored heat into the pipes. During the nighttime, the greenhouse
air was warmed up and increased in temperature by 4 ̄5.5 and in enthalpy by 7 ̄10kJ/kg,
after flowed through the pipes and gained heat from the soil. When the system was run at night,
it could give heat for about 60W/m2 (greenhouse floor) and the inside air temperature of the
greenhouse was 11 or higher than outside temperature.
出处
《农业工程学报》
EI
CAS
CSCD
北大核心
1999年第2期160-164,共5页
Transactions of the Chinese Society of Agricultural Engineering
基金
国家"九五"工厂化农业重大科技产业工程项目
关键词
连栋温室
地中热交换系统
贮热
加温
节能
温室
multispan
greenhouse,underground heat exchange system,heat storage,heating,energy saving