以自制的不同浓度的酸性重铬酸钠溶液为合成废水,利用准液膜法从废水中提取Cr(Ⅵ),并用提取后剩余溶液中Cr(Ⅵ)的浓度表征处理效果.结果表明∶当废水中铬含量在400mg/L以下时,经一次提取,铬含量在800mg/L时,则需2次提取,提取余液中Cr(Ⅵ)的含量均降至5mg/L左右;当碱液呈喷雾状下落时,提取效果更好.
Cr() was extracted from the wastewater by pseudo liquid membrane method,which the wastewater was composed of a variety of concentration of sodium dichromate in acidic aqueous solution. The extracting results were charactered by means of the Cr() in remaining solution. When Cr() was lower than 400 mg\5L\+\{-1\} in the wastewater, extraction for one time, and Cr() was 800 mg\5L\+\{-1\}, extraction for twice ,the results showed that the concentration of Cr() in remaining solution is 5 mg\5L\+\{-1\} or so. As the basic solution sprays falling, the results were well. This method will be pontential to handle industrial wastewater containing Cr().\=