期刊文献+

非球面人工晶状体植入眼的视觉质量分析

Optical quality analysis of aspheric intraocular lens
原文传递
导出
摘要 目的 观察非球面人工晶状体(IOL)、球面IOL植入眼与正常中青年人眼的波前像差和对比敏感度差异.方法 46例(49只眼)老年性白内障患者随机分成两组,分别植入非球面IOL Acrysof IQ(SN60WF)和球面IOL Acrysof Nature(SN60AT).随机选择同期正常中青年人(年龄20~40岁)作为对照组.分别对术后3月的患者和对照组进行最佳矫正视力、像差和对比敏感度检查.结果 IQ组的球差显著小于Natural组(P <0.05),而和正常中青年组比较无统计学意义(P >0.05);两IOL组的高阶像差和慧差均显著大于正常中青年组(P <0.05).非眩光状态下,IQ组在低频时(6.3degrees)的对比敏感度显著高于Natural组(P <0.05),和正常中青年组比较无统计学意义(P >0.05);眩光状态下,IQ组在低频时(6.3和4.0degrees)的对比敏感度显著高于Natural组(P <0.05),两IOL组在所有视角下的对比敏感度均显著低于正常中青年组(P <0.05).结论 非球面IOL植入能使白内障患者术后眼内球差明显减小,非眩光状态下低频时的对比敏感度明显提高,更接近正常中青年人眼水平,具有比球面IOL更佳的视觉质量. Objective To study the optical wavefront aberrations and contrast sensitivity in eyes treated with uneventful cataract surgery with in-the-bag implantation of an aspheric Acrysof IQ intraocular lens (IOL) or a spherical Acrysof Natural IOL, and compare the results with those in a group of normal young-middle aged eyes. Methods Forty-six patients with age-related cataract (49 eyes) were randomly divided into two groups: Acrysof IQ IOL group included 27 patients (29 eyes) and Acrysof Natural IOL group included 19 patients (20 eyes). Normal 30 young-middle aged people (30 eyes) were selected as a control group. The wavefront aberrations and contrast sensitivity were evaluated in 3 months of postoperative patients and in normal control group. Results There was no statistical significance of the mean internal spherical aberration between IQ and control group, but was statistically lower than Natural group (P 〈0.05). The mean internal high order aberration and coma between IQ and Natural group were similar (P 〉0.05), but statistically higher than those of control group (P 〈0.05). The contrast sensitivity (CS) of IQ group was similar to control group in low spatial frequency (6.3degrees, nor glare)(P 〉0.05), but was statistically lower than control group in other spatial frequency (P 〈0.05), as well as the results of Natural group in all spatial frequency (under the condition of glare or not)(P 〈0.05). CS of Natural group were significantly lower than IQ group in low spatial frequency (6.3degrees, no glare; 6.3 and 4.0 degrees, glare)(P 〈0.05), but without any statistical significance in other spatial frequency. Conclusions IQ Aspheric IOL can not only reduce the spherical aberration of eyes after cataract surgery, but also improve the contrast sensitivity, suggesting aspheric IOL is much better than spherical IOL.
出处 《中国实用眼科杂志》 CSCD 北大核心 2010年第8期825-829,共5页 Chinese Journal of Practical Ophthalmology
关键词 非球面 人工晶状体 对比敏感度 波前像差 Aspheric Intraocular lens(IOL) Contrast sensitivity Aberration
  • 相关文献

参考文献16

  • 1曾明兵,刘奕志,柳夏林,袁钊辉,罗莉霞,王毓林,刘恬.非球面单焦点及多焦点人工晶体眼高阶像差及对比敏感度比较[J].中国实用眼科杂志,2007,25(3):253-256. 被引量:9
  • 2石栋,董雅娟,张劲松.波前像差技术在白内障及人工晶体中的应用[J].中国实用眼科杂志,2006,24(4):362-367. 被引量:2
  • 3Oshika T,Klyce SD,Applegate RA,et a1.Changes in corneal wavefront aberrations with aging[J].Invest Ophthalmol Vis Sci,1999,40:1351-1355.
  • 4Awwad ST,El-Kateb M,Bowman RW,et a1.Wavefront-guided laser in situ keratomileusis with the Alcon CustomCornea and the VISX CustomVue:three-month results[J].J Refract Surg,2004,20:606-613.
  • 5Mester U,Dillinger P,Anterist N.Impact of a modified optic design on visual function:clinical comparative study[J].J Cataract Refract Surg,2003,29:652-660.
  • 6Holladay J T,Piers PA,Koranyi G,et a1.A new intraocular lens design to reduce spherical aberration of pseudophakic eyes[J].J Refract Surg,2002,18:683-691.
  • 7Packer M,Fine IH,Hoffman RS.Wayefront technology in cataract surgery[J].Curr Opin Ophthalmo1,2004,15:56-60.
  • 8Karolinne MR,Eduardo SS,Maria RC,et al.Wavefront Analysis and Contrast Sensitivity of Aspheric and Spherical Intraocular Lenses A Randomized Prospective Study[J].American Journal of Ophthalmology,2006,142:750-756.
  • 9鲍连云,何伟,刘文辉,徐茂生.屈光性弱视与屈光参差性弱视对比敏感度变化的比较[J].眼科研究,2001,19(2):147-149. 被引量:27
  • 10Levy Y,Segal O,Avni I,et al.Ocular higher-order aberrations in eyes with supernormal vision[J].Am J Ophthalmol,2005,139:225-228.

二级参考文献72

  • 1李凤鸣.眼科全书(第1版)[M].北京:人民卫生出版社,1996.1932.
  • 2Seiler T,Dastjerdi MH.Customized corneal ablation.Curr Opin Ophthalmol.2002 Aug;13(4):256-60
  • 3Jim S.Theoretical limits to visual performance.Surv Ophthalmol.2000;45:139-46
  • 4Artal P.Towards "super-vision":Facts and fiction.Points devue.2002;46:3-16
  • 5Huang D.Physics of customized corneal ablation.In:Scott M,ed.Customized Corneal Ablation.Thorofare:SLACK,2001;51-62
  • 6Thibos LN.Wavefront data reporting and terminology.J Refract Surg.2001 Sep-Oct;17(5):578-83
  • 7Awwad ST,E1-Kateb M,Bowman RW,et al.Wavefront-guided laser in situ keratomileusis with the Alcon CustomCornea and the VISX CustomVue:three-month results.J Refract Surg.2004 SepOct;20(5):606-13
  • 8Webb R,Penny CM,Thompson K.Measurement of ocular local wavefront distortion with a spatially resolved refractometer.Applied Optics.1992;31:3678-86
  • 9Smirnov HS.Measurement of the wave aberration of the human eye.Biofizika.1961;6:776-95
  • 10Walsh G,Charman WN,Howland HC.Objective technique for the determination of monochromatic aberrations of the human eye.J Opt Soc Am A.1984 Sep;1 (9):987-92

共引文献35