期刊文献+

Effect of vacuum degree and aeration rate on sludge dewatering behavior with the aeration-vacuum method 被引量:3

Effect of vacuum degree and aeration rate on sludge dewatering behavior with the aeration-vacuum method
原文传递
导出
摘要 Due to large-scale dredging operations, a large amount of sludge is inevitably produced. Large areas of land are occupied when the dredged sludge is discarded in the disposal site as waste material. The sludge dewatering with aeration-vacuum (SDAV) method is suit for treating the sludge with high water content and high clay content in the disposal site. The water in the sludge can be discharged out. The volume of the sludge can be reduced quickly, and the recycling of the land can be accelerated by this method. Most importantly, this technique is an efficient way to deal with clogging problems when pumping water from high water content, high clay content dredged sludge. Vacuum degree range tests, the aeration rate range tests, and the influencing factors of sludge dewatering behavior tests were conducted with a self-developed SDAV model test device. Sludge samples were taken from the South-to-North Water Diversion East Line Project in Huai’an White-Horse Lake disposal site, Jiangsu Province, China. The optimal range of vacuum degree and aeration rate were obtained through the test results, and the mechanisms for how the two factors work and how they affect the sludge dewatering behavior were analyzed. The suitable vacuum degree range in SDAV is below 50 kPa, and the suitable aeration rate is about 1.0 m3/h. The low-vacuum degree contributes to reduce the ad-sorption effect of micro-channels on soil particles in filter material and to maintain the arch structures. Aeration has the effects of expansion, disturbance, changing Reynolds number, and dynamic sieve separating. The pump quantity of water per meter of filter tube (m) has different change rules as the vacuum degree changes under different aeration rates. The reason is that the formed arch structures’ conformation and permeability differ greatly under different combined-conditions of vacuum degree and aeration rate. The optimal combined-condition for dewatering the sludge is 35 kPa with 1.0 m3/h. Due to large-scale dredging operations, a large amount of sludge is inevitably produced. Large areas of land are occupied when the dredged sludge is discarded in the disposal site as waste material. The sludge dewatering with aeration-vacuum (SDAV) method is suit for treating the sludge with high water content and high clay content in the disposal site. The water in the sludge can be discharged out. The volume of the sludge can be reduced quickly, and the recycling of the land can be accelerated by this method. Most importantly, this technique is an efficient way to deal with clogging problems when pumping water from high water content, high clay content dredged sludge. Vacuum degree range tests, the aeration rate range tests, and the influencing factors of sludge dewatering behavior tests were conducted with a self-developed SDAV model test device. Sludge samples were taken from the South-to-North Water Diversion East Line Project in Huai’an White-Horse Lake disposal site, Jiangsu Province, China. The optimal range of vacuum degree and aeration rate were obtained through the test results, and the mechanisms for how the two factors work and how they affect the sludge dewatering behavior were analyzed. The suitable vacuum degree range in SDAV is below 50 kPa, and the suitable aeration rate is about 1.0 m3/h. The low-vacuum degree contributes to reduce the ad-sorption effect of micro-channels on soil particles in filter material and to maintain the arch structures. Aeration has the effects of expansion, disturbance, changing Reynolds number, and dynamic sieve separating. The pump quantity of water per meter of filter tube (m) has different change rules as the vacuum degree changes under different aeration rates. The reason is that the formed arch structures’ conformation and permeability differ greatly under different combined-conditions of vacuum degree and aeration rate. The optimal combined-condition for dewatering the sludge is 35 kPa with 1.0 m3/h.
作者 Yu-feng GAO
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第9期638-655,共18页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 Project supported by the National Natural Science Foundation of China (No. 50879023) the National Hi-Tech Research and Development Program (863) of China (No. 2007AA11Z135) the Min-istry of Water Resources Nonprofit Public Industry Special Foundation of China (No. 200701045)
关键词 High water content dredged sludge Sludge dewatering with aeration-vacuum (SDAV) Vacuum degree Aeration rate Arch structures High water content dredged sludge, Sludge dewatering with aeration-vacuum (SDAV), Vacuum degree, Aeration rate, Arch structures
  • 相关文献

参考文献5

二级参考文献17

  • 1陈轮,易华强,许齐,庄艳峰.土工织物反滤系统土体结构稳定性模拟试验研究[J].水力发电学报,2006,25(4):117-121. 被引量:16
  • 2南水北调东线第一期工程可行性研究报告[R].2005.
  • 3邓东升,洪振舜,朱伟,等.高含水率疏浚淤泥堆场透气真空快速泥水分离方法.中国:200710132092.9[P].2007.
  • 4JTJ051--93公路土工试验规程[S].1993.
  • 5GB8978--96污水综合排放标准[S].1997.
  • 6王钊.国外土工合成材料的应用研究[M].北京:现代知识出版社,2002.234-244.
  • 7Giroud J P.Granular filters and geotextile filters[A].The Proceeding of the Fifth China Conference on Geosynthetics (Selected Papers from Foreign Countries)[C],CTAG,CCIGS,Yichang,Hubei,2000:54~ 167.
  • 8Palmeira E M,Fannin R J.Soil-geotextile compatibility in filtration.Geosynthetics[A].Proc 7th Intl Conf on Geosynthetics[C].Nice,France.2002,3:853 ~ 870.
  • 9Watson P D J,John N W M.Geotextile filter design and simulated bridge formation at the soil-geotextile interface[J].Geotextiles and Geomembranes,1999,(17):265 ~ 280.
  • 10Lawson C R. Geotextile revetment filters [ J ]. Geotextiles and Geomembranes, 1991,11 (4-6) : 431 - 448.

共引文献50

同被引文献23

引证文献3

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部