期刊文献+

双层串联微穿孔板消声器的设计与试验 被引量:14

Design and Test of a Double Layer Micropunch Plate Muffler
下载PDF
导出
摘要 针对某抽气泵排气噪声从高于80dB(A)降低到72dB(A)以下的要求,应用微穿孔板吸声体理论,设计双层串联微穿孔板消声器,并制作样件进行试验。结果表明安装消声器后,最大噪声值不超过67dB(A)。且在1000Hz~2500Hz频段,噪声下降尤为明显,消声量达到了10dB(A)~20dB(A),满足了设计的目标,验证了理论与实际的一致性。 An air extracting pump is required to reduce the noise from 80 dB ( A) to 72 dB ( A) . To solve the problem,a double layer micropunch plate muffler is designed on the basis of the theory of microperforated panel absorber and a sample is made for test. The results show that with installation of the muffler,the maximum noise is less than 67 dB ( A) . The noise is dropped obviously between 1,000 Hz ~ 2,500 Hz and sound deadening capacity reaches to 20 dB( A) . The results fully achieve the design objective and verify the consistency of theory and practice.
出处 《机械科学与技术》 CSCD 北大核心 2010年第8期1094-1096,共3页 Mechanical Science and Technology for Aerospace Engineering
基金 国家"十一五"863计划项目(2009AA064805)资助
关键词 双层串联微穿孔板 消声器 设计 试验 double layer micropunch plate muffler design test
  • 相关文献

参考文献8

二级参考文献13

  • 1马大猷.高声强下的微穿孔板[J].声学学报,1996,21(1):10-14. 被引量:25
  • 2马大猷.微穿孔板吸声结构的理论和设计[J].中国科学,1975,18(3):38-50.
  • 3马大猷.微穿孔板结构的设计.声学学报,1988,13:147-180.
  • 4Maa D Y. Microperforated-Panel wideband absorbers [ J ]. Noise Control Eng., 1987,29(3) :77-84
  • 5Maa D Y. Potential of microperforated panel absorber [ J ]. J. Acoust. Soc. Am., 1998,104(5):2861 -2865
  • 6ZHANG Z M. The theoretical and application study on a double layer microperforated sound absorption structure [J]. Applied Acoustic, 1998,215 (3) : 399-405.
  • 7赵松龄.噪声的降低与隔离(上册)[M].上海:同济大学出版社,1985..
  • 8赵松龄 卢元伟.关于穿孔板的非线性声阻.物理学报,1978,9(5):600-603.
  • 9王鹏,王敏庆,樊晓波.温度变化条件下微穿孔板声学特性研究[J].振动.测试与诊断,2007,27(4):267-269. 被引量:4
  • 10马大猷.微穿孔板吸声体的准确理论和设计[J].声学学报,1997,22(5):385-394. 被引量:179

共引文献101

同被引文献117

引证文献14

二级引证文献63