摘要
针对高压泵机组的电机振动严重超标的故障,通过测试数据采集分析,结合现场安装调整提高基础板结构的刚度,有效地解决了该电机异常振动故障。
There were excessive vibration faults in motor of the high voltage pump unit.On the basis of analysis of acquired data,rigidity of the basic plate structure was increased in field installation.It effectively eliminated unusual vibration of this motor.
出处
《冶金动力》
2010年第4期10-12,共3页
Metallurgical Power
关键词
电机
振动
频谱
基础板结构
对中
motor
vibration
frequency spectrum
basic plate structure
alignment