通过对电厂主机和主要辅机非计划停运的主要原因、主要系统拟订方案的分析研究,提出了保证600MW机组可用率达到95%、利用率可以达到80%的方案。
The main reasons of the unplanned outage of the main and auxiliary equipments in power plant were analyzed, and the prepared schemes of main systems were researched. Based on these, the scheme was put forward, which can ensure the availability rate of the 600 MW unit to be not less than 95% and the utilization rate to be not less than 80%.
出处
《华电技术》
CAS
2010年第8期18-22,29,共6页
HUADIAN TECHNOLOGY
关键词
600MW机组
可用率
利用率
控制方案
600 MW unit
availability rate
utilization rate
control scheme