摘要 介绍了在实验室规模的三维冷态试验台上,用黄砂作床料,用激光粒子动态分析仪(PDA)测定新型流化床颗粒层过滤器(圆柱形过滤元件)过滤性能的试验研究的结果。研究结果表明,在实验条件下,经新型流化床颗粒层过滤器过滤后的清洁气流中,微细尘粒的平均粒径为5μm左右,体积流量为0.908×10-4cm3/(s·cm-2)左右。 Experimental study on the filtration performance of a novel granular filter in fluidized bed is introduced in this paper.The experiments were conducted on a 3 dimension lab scale granular filter facility with a filter unit supported by a round column.When river sand served as bed material,the mean diameter and the volume flux of the particle in the filtrated clean gas are respectively about 5 micron,9.08×10 -5 cm 3/(s·cm -2 ),measured with Dantec 3 dimension laser particle dynamics analyzer(PDA),which suggest that the granular filter works effectively.
出处 《中国电机工程学报》 EI CSCD 北大核心 1999年第7期53-56,共4页 Proceedings of the CSEE
基金 湖北省自然科学基金 煤燃烧国家重点实验室开放基金
关键词 煤气净化装置 颗粒层过滤器 流化床 过滤性能 granular filter fluidized bed filtration effect