摘要
本文通过对某热电厂全厂停电事故的描述和原因及改进措施的分析,探讨了发电机组机端静态励磁和无刷励磁的特点和应用场合,通过实例阐述了励磁方式的选择对电力系统稳定性的重要性。
This paper discuss the specialty and application of static excitation and brushless excitation of generator terminal through description and analysis of reason and improvement of the accident of complete plant black-out in one thermal electric power plant. Through the example, this paper clarifies the importance to electric power system stability of excitation mode.
出处
《电力勘测设计》
2010年第4期53-56,共4页
Electric Power Survey & Design
关键词
机端静态励磁
不独立性
无刷励磁
独立性
电力系统稳定性
static excitation of generator terminal
dependence
brushless excitation
independence
electric power system stability.