摘要 目的探讨影响泌乳素浓度的原因。方法用电化学发光法:(1)同时检测两个不同采血时间段所得标本的泌乳素含量;(2)检测经聚乙二醇处理前后的泌乳素含量。结果两个不同时间段的泌乳素含量间差异有统计学意义(P<0.05);53例高泌乳素血清中检出含巨泌乳素有13例,含巨泌乳素的标本经聚乙二醇处理前后泌乳素含量差异有统计学意义(P<0.05)。结论确定采血时间,去除巨泌乳素的干扰,有助于高泌乳素血症的判断和确诊。
作者 秦辛玲
出处 《检验医学与临床》 CAS 2010年第16期1719-1720,共2页 Laboratory Medicine and Clinic
  • 相关文献

参考文献5

二级参考文献7

  • 1周慧,窦京涛,郭爱岩,汪寅章.高泌乳素血症的临床分析[J].标记免疫分析与临床,1995,2(3):177-177. 被引量:1
  • 2George N.KouKoulis:Macroprolactine mia an unnoticeable factor[J].Hormones,2003,2 (2):91-92.
  • 3Mark WJ,Strachan,Weileng Teoh,et al.Donauchope clinical and radiological feature of patients with maroprolactinae mia[J].Clinical Endocrinology,2002,59:339-346.
  • 4Mchael N.Fahine-wilson polyethlene glycol precipitiation as a screening method for macroprolactine mia[J].Clinical Chemistry,1999,45:436-437.
  • 5Vieira JG, Tachibana TT, Obara LH, et al. Extensive experience and validation of polyethylene glycol precipitation as a screening method for macroprolactinemia. Clin Chem, 1998,44:1758 - 1759
  • 6Leslie H, Courtney CH, Bell PM ,et al. Laboratory and clinical experience in 55 patients with macroprolactinemia identified by a simple polyethylene glycol precipitation method. J Clin Endocrinol Metab,2001, 86:2743 - 2746
  • 7Fahie- Wilson MN, Soule SG. Macroprolactinaemia: contribution to hyperprolactinaemia in a district general hospital and evaluation of a screening test based on precipitation with polyethylene glycol. Ann ClinBiochem ,1997,34(2 ) : 252 - 258

共引文献18

同被引文献23

  • 1Fahie Wilson M, Brunsden P, Surrey J, et al. Macroprolactin and the Roche Elecsys prolactin assay characteristics of the reaction and detection by precipitation with polyethylene glycol[J]. Clin Chem,2000,46(12) : 1993-1995.
  • 2Leslie H, Courtney CH, Bell PM, et al. Laboratory and clinical ex- perience in 55 patients with macroprolactinemia identified by a simple polyethylene glycol precipitation method[J]. J Clin Endo- crinol Metab,2001,86(6):2743-2746.
  • 3Amadori P, Dilberis C, Marcolla A, et al. Macroprolactinemia: pre- dictability on clinical basis and detection by PEG precipitation with two different immunometric methods[J]. J Endocrinol In- ves,2003,26(2) 148-156.
  • 4McKerma TJ. Should macroprolactin be measured in all hyperpro lactinaemic sera? [J]. Clin Endoerinol ( Oxf), 2009, 71 ( 4 ) : 466 -469.
  • 5Fahie Wilson M, Brunsden P, Surrey J,et al. Macropro-lactin and the roche elecsys prolactin assay:Characteris-tics of the reaction and detection by precipitation with po-lyethylene glycol[J]. Chin Chem,2000,46:1993-1995.
  • 6Leslie H, Courtney C H,Bell P M, et al. Laboratory andclinical experience in 55 patients with macroprolactinemiaidentified by a simple polyethylene glycol precipitationmethod[J], J Clin Endocrinol Metab,2001,86 ;2743-2746.
  • 7Amadori P,Dilberis C, Marcolia A, et al. Macropro-lactinemia:predictability on clinical basis and detectionby PEG precipitation with two different immunometricmethods[J]. J Endocrinol Invest, 2003,26(2):148-156.
  • 8Me Kerma T J. Should macroprolactin be measured in allhyperprolactinaemic sera? [ J]. Clin Endocrinol (Oxf),2009,71(4):466-469.
  • 9Amadori P, Dilberis C, Marcolla A, et al. Macroprolactinemia: predictability on clinical Basis and detection by PEG precipitation with two different immunometric methods. J Endocrinol Invest, 2003, 26 (2) : 148- 156.
  • 10Fahic-Wilson MN. Polyethylene glycol precipetation as screening method for macroprolactinemia. Clin Chem, 1999, 45 (3) : 436-437.