摘要 尘埃粒子计数器主要用来评定洁净室洁净度等级、检测过滤器的过滤效率及洁净织物的发尘量等。尘埃粒子计数器的量值溯源因其特殊性,存在很大难度,多年来国内外都在致力于尘埃粒子计数器的校准研究。该文就研究以及编写的尘埃粒子计数器国家计量校准规范,来阐述尘埃粒子计数器的校准方法。 The airborne particle counter is an important instrument used widely in the clean area,mainly be used to assess the cleanliness classes for clean rooms and clean zones,also be used to test the filtration efficiency filter,the particle counter of the fabric for clean room garment systems and the like.Traceability of airborne particle counter has its own specialty,there is a big difficulty,at home and abroad many people are working to the calibration of airborne particle counter for many years.In this paper I prepared sector research and calibration specification for airborne particle counter,to elaborate calibration method for airborne particle counter.
作者 刘悦
出处 《上海计量测试》 2010年第4期7-10,共4页 Shanghai Measurement and Testing
关键词 尘埃粒子计数器 校准 量值溯源 标准粒子 标准粒子发生装置 airborne particle counter calibration traceability standard particles the standard particle generating device
  • 相关文献

参考文献7

  • 1杨娟,卞保民,何幼权,贺安之,王亚伟.尘埃粒子计数器粒子散射光信号幅度概率分布[J].光电子.激光,2001,12(1):67-70. 被引量:6
  • 2JIS. B9921-1997[S]. JAPAN: 1997.
  • 3ASTM. F328-98[S]. USA: 1998.
  • 4ASTM. F649-80[S]. USA: 1980.
  • 5VDI. 3489-1997[S]. Germany: 1997.
  • 6全国暖通空调及净化设备标准化技术委员会.GB6167-2007[s].北京:中国标准出版社,2008.
  • 7全国环境化学委员会.JJF1190-2008[S].北京:中国计量出版社,2008.

二级参考文献3