该文通过介绍接触电流,引出相关标准中对应的测试接触电流所需的三种模拟人体阻抗网络,对其计量属性进行分析,提出了几种校准方法,并对测得的数据进行分析,选择最佳的校准方法以及所必需配置的仪器。
This essay first defines the touch current,then introduces three kinds of measuring devices(MDs) according to relevant standards,and analyzes the measuring attributes of the three MDs.After that,this essay puts forward several calibration methods.By comparing the calibration results,it concludes with the best calibration method and necessary instruments.
出处
《上海计量测试》
2010年第4期18-22,共5页
Shanghai Measurement and Testing
关键词
接触电流
模拟人体阻抗网络
校准
高频电流
touch current
measuring device(MD)
calibration