期刊文献+

利用双差压式节流装置测量湿气 被引量:16

Wet gas metering using double differential pressure device
下载PDF
导出
摘要 为实现湿气气液两相的在线不分离测量,提出一种由内锥和文丘里组合构成的新型双差压式湿气测量装置,并进行了实验研究。针对内锥及文丘里湿气虚高值的特点,建立了基于Lockhart-Martinelli参数、Froude数、气液密度比的内锥高精度虚高模型;建立了文丘里Deleeuw修正模型,实现了对n值的高精度拟合。通过对内锥和文丘里管在湿气测量中气液两相精度的对比分析,建立了湿气气液两相测量的迭代修正算法。实验结果表明,对于压力P为0.1~0.2MPa,气相弗劳德数0.6~1.5,L-M参数0.002~0.12,质量含气率在30%~99%范围内,气相流量测量的平均相对误差优于±1%,液相流量测量的满度误差小于±10%。 In order to measure the gas and liquid flow rates of wet gas flow without separation on line,a novel double differential pressure device composed of one cone device and one Venturi tube for metering wet gas is presented here,and experimental research was carried out.Considering the overreading performance of Wafer-cone and Venturi,an overreading model for high accuracy cone differential pressure device based on Lockhart-Martinelli parameter,Froude number,density ratio of gas and liquid is put forward.A modified Deleeuw overreading model for Venturi differential pressure device was built,in which the polynomial representation of "n" value is given.Through comparing the metering accuracies of gas flow rates and liquid flow rates of cone flow meter and Venturi flow meter,respectively,a wet gas metering iteration algorithm for gas and liquid flow rates is obtained.Experiment results show that the mean relative error of gas flow rates is less than ±1% and full scale error of liquid flow rates is less than ±10% under the condition that the test pressure range is 0.1 MPa to 0.2 MPa,Froude number range is 0.6 to 1.5,L-M number range is 0.002 to 0.12,and gas mass rate range is 30% to 99%.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2010年第8期1840-1847,共8页 Chinese Journal of Scientific Instrument
基金 国家高技术研究发展计划(863计划)(2007AA04Z180) 天津市应用基础与面上项目(200708JCYBJC11800) 国家自然科学基金(60974118)资助项目
关键词 内锥 文丘里 双差压节流装置 湿气测量 虚高模型 迭代 cone Venturi double differential pressure device wet gas metering overreading model iteration
  • 相关文献

参考文献22

  • 1LAWRENCE P A,STEVEN R.Research development in wet gas metering with V-cone meters[J].North Sea Flow Measurement Workshop,2003.
  • 2MURDOCK J W.Two-phase flow measurement with orifices[J].Journal of Basic Engineering,1962,84(4):419-433.
  • 3DE LEEUW H.Wet gas flow measurement using a combination of Venturi meter and a tracer technique[C].North Sea Flow Measurement Workshop,Peebles,Scotland,1994.
  • 4FERREIRA V C S.Differential pressure spectral analysis for two-phase flow through an orifice plate[J].Int.J.Pres.Ves.& Piping,1997,73:19-23.
  • 5CHISHOLM D J.Flow of incompressible two-phase mixtures through sharp-edged orifices[J].Journal of Mechanical Engineering Science,1967,9(1):72-78.
  • 6CHISHOLM D J.Research note:Two-phase flow through sharp-edged orifices[J].Journal of Mechanical Engineering Science,1977,19(3):128~130.
  • 7De LEEUW H.Liquid correction of venturi meter readings in wet gas flow[C].North Sea Flow Measurement Workshop,Norway,1997.
  • 8LUO Y.The study of wet gas measurement technology for applications:Venturi tube[D].Tianjin:Tianjin University,2005.
  • 9FANG L D.Gas-liuqid two-phase flow measurement based on a slot venturi device[D].Tianjin:Tianjin Univer-sity,2007.
  • 10WEI M.Study of the wet gas measurement technique based on two traditional flowmeters[D].Tianjin:Tianjin University,2004.

二级参考文献41

  • 1林军,董守平,黄辉.多相流量计测单元阻力模型实验研究[J].实验流体力学,2005,19(1):26-30. 被引量:1
  • 2耿艳峰,冯叔初,郑金吾.槽式孔板的气液两相压降倍率特性[J].化工学报,2006,57(5):1138-1142. 被引量:10
  • 3IFFT S A, MIKKELSEN E D. Pipe elbow effects on the V-cone flowmeter[ C ]. ASME Fluids Engineering Conference, Washington D. C., 1993.
  • 4SINGH S N, SESHADRI V, SINGH R K, et al. Effect of upstream flow disturbances on the performance characteristics of a V-cone flowmeter [ C ]. Flow Measurement and Instrumentation, 2006, 17: 291-297.
  • 5PETERS R J W, STEVEN R, CALDWELL S, et al. Testing the wafer V-cone flowmeters in accordance with API 5.7 "Testing Protocol for Differential Pressure Flow Measurement Devices" in the CEESI Colorado test facility[ J]. Flow Measurement and Instrumentation, 2006, 17 : 247-254.
  • 6DR PETERS R J W. Flow t technology manager, mccrometer casey hodges - staff engineer, CEESI testing the wafer V-cone flowmeters in accordance with API 22.2 "Testing Protocol for Differential Pressure Flow Measurement Devices"[ R]. At the CEESI Colorado Test Facility 6th ISFFM May 16-18, 2006.
  • 7YAKHOT V, ORSZAG S A, Renormalization grou Panalysis of turbulence : I. Basic theory[ J]. Journal of Scientific Computing, 1986, 1 (1) : 1-51.
  • 8GAN G, RIFFAT S B. K-factors for HVAC ducts-numerical and experimental determination [ J ]. Building Services Engineering Research and Technology, 1995, 16 (3) : 133-139.
  • 9INTERNATIONAL STANDARD ISO 5167-2 2nd edition. Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full-Part1 : General Principles and requirements [ S ]. 2003 -03 -01.
  • 10Lin Zonghu(林宗虎).Gas-Liquid Two-phase Flow and Heat Exchangers(气液两相流和沸腾传热).Xi'an:Xi'an Jiaotong University Press,2003