以5-溴-4-氯-3-吲哚磷酸盐和氯化硝基四氮唑蓝为底物,建立ALP活力比色测定法。线性下限0.2U/L(皮-劳法);两份标本CV值批内为1.07%和1.59%,批间为4.13%和4.38%;与皮-劳法(连续监测法)结果比较,相关系数为0.992。结果表明,此法简便、可靠、灵敏。
A colorimetric method for measuring alkaline phosphatase (ALP)
activity with
BCIP and NBT as substrates was established. The low limit of detection is 0 2 U/L (Bessy
Lowry
method). The within run CVs of two levels of ALP activity (5 0、1 0 U/L) are 1 07% and 1 59%,
between run CVs 4 13% and 4 38%, respectively. The correlation coefficient between this
method
and Bessy Lowry method (kinetic) is 0 992. The results showed that this method was simple,
reliable and sensitive.