期刊文献+

动脉自旋标记MR灌注成像及其在肌骨系统的应用 被引量:2

下载PDF
导出
摘要 动脉自选标记(arterial spin labeling,ASL)灌注成像是近年来发展起来的MR灌注成像新技术,可测量组织血流量的绝对值,在临床和基础研究中有广阔的应用前景。
出处 《影像诊断与介入放射学》 2010年第4期238-240,共3页 Diagnostic Imaging & Interventional Radiology
  • 相关文献

参考文献20

  • 1Petersen ET, Zimine I, Ho YC, et al. Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques. Br J Radiol, 2006,79: 688-701.
  • 2冯锡钢,林意群.磁共振动脉自旋标记灌注成像[J].中国医学装备,2005,2(3):45-51. 被引量:8
  • 3张冬,冯晓源,邹利光.动脉血质子自旋标记磁共振灌注成像[J].中国医学计算机成像杂志,2008,14(1):79-82. 被引量:6
  • 4Golay X, Hendrikse J, Lim TC. Perfusion imaging using arteria/spin labeling. Top Magn Reson Imaging, 2004,15: 10-27.
  • 5Detre JA, Leigh J S, Williams DS, et al. Perfusion imaging. Magn Reson Med, 1992,23:37--45.
  • 6Detre JA, Alsop DC, Vives LR, et al. Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease. Neurology, 1998,50: 633-641.
  • 7Edelman RR, Siewert B, Darby DG, et al. Qualitative mapping of cerebral blood flow and functional localization with echo-planar imag ing and signal targeting with alternating radio frequency. Radiology, 1994,192: 513-520.
  • 8Kwong KK, Chesler DA,Weisskoff RM, et al. MR perfusion studies with T1-weighted echo planar imaging. Magn Reson Med, 1995,34: 878-887.
  • 9Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med, 1995,34:293- 301.
  • 10WolfRL, Detre JA. Clinical neuroimaging using arterial spin labeled perfusion magnetic resonance imaging. Neurotherapeutics, 2007,4: 346-350.

二级参考文献54

  • 1[1]Detre JA,Leigh JS,Williams DS,Koretsky AP (1992) Perfusion Imaging.Magn Reson Med23:37-45.
  • 2[2]Roberts DA,Detre JA,Bolinger L,Insko EK,Leigh JS (1994)Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water.Proc Nat Acad Sci (USA) 91:33-37.
  • 3[3]http://www.ujf-grenoble.fr/ismrm/ASL/reference # Kely1951
  • 4[4]Williams DS,Detre JA,Leigh JS,Koretsky AP (1992) Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proc Nat Acad Sci (USA) 89:212-216.
  • 5[5]Dixon WT,Du LN,Faul DD,Gado M,Rossnick S (1986)Projection angiograms of blood labeled by adiabaic fast passage.Magn Reson Med 3:454-462.
  • 6[6]Maccotta L,Detre JA,Alsop DC.The efficiency of adiabatic inversion for perfusion imaging by arterial spin labeling.NMR Biomed 1997;10:216-221.
  • 7[7]Edzes HT,Samulski ET (1978) The measurement of crossrelaxation effects in the proton NMR spin-lattice relaxation of water in biological systems:hydrated collagen and muscle.J Magn Reson 31:207-229.
  • 8[8]Alsop DC,Detre JA (1998) Multislice cerebral blood flow MR imaging with continuous arterial spin labeling,Radiology 208:410-416.
  • 9[9]Rosen BR,Belliveau JW,at al,Perfusing imaging with NMR contrast agents.MRM 14:249-265,1990
  • 10[10]Edelman RR,Siewert B,Darby DG,Thangaraj V,Nobre AC,Mesulam MM,Warach S (1994) Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.Radiology192:513-520.

共引文献14

同被引文献47

  • 1吴仁华,Vu Mai,陈小轲,Armisted Williams,David Kallmes.附加射频的流敏交替反转回波序列无损伤地测定兔VX2肿瘤的血流灌注[J].中华放射学杂志,2005,39(3):313-316. 被引量:5
  • 2Garc~a-figueiras R, Goh V J, Padhani AR, et al. CT perfusion in oncologic imaging: a useful tool? Am J Roentgenol,2013,200: 8-19.
  • 3Goh V, Padhani AR. Imaging tumor angiogenesis: functional assessment using MDCT or MRI? Abdom Imaging, 2006, 31 : 194- 199.
  • 4Sourbron S. Technical aspects of MR perfusion. Eur J Radiol, 2010,76: 304-313.
  • 5Boxerman JL, Schmainda KM, Weisskoff RM. Relative cerebral blood volume maps corrected for contrast agent extravasation significantly correlate with glioma tumor grade, whereas uncorrected maps do not. Am J Neuroradiol, 2006, 27: 859-867.
  • 6Sourbron S, Heilmann M, Biffar A, et al.Bolus-tracking MRI with a simultaneous T1- and T2*-measurement. Magn Reson Med, 2009, 62 : 672-681.
  • 7Fayad LM, Jacobs MA, Wang X, et al. Musculoskeletal tumors: how to use anatomic, functional, and metabolic MR techniques. Radiology, 2012, 265 : 340-356.
  • 8Wirestam R, Borg M, Brockstedt S, et al. Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique. Acta Radiol, 2001, 42 : 123-128.
  • 9Erlemann R, Reiser MF, Peters PE, et al. Musculoskeletal neoplasms: static and dynamic Gd-DTPA-enhanced MR imaging. Radiology, 1989,171 : 767-773.
  • 10Hawighorst H, Lihicher M, Knopp MV,et al. Evaluation of angiogenesis and perfusion of bone marrow lesions: role of semiquantitative and quantitative dynamic MRI. J Magn Reson Imaging, 1999,10: 286-294.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部