摘要
介绍了惠州抽水蓄能电站机组振动在线监控系统的配置情况,在机组调试过程中分析并排除了影响该系统数据测量的干扰信号,以保证测量数据能够真实准确地反映机组的振动状态。根据对惠蓄机组振动特性的分析,提出几点相似型式抽水蓄能机组在动平衡试验中应注意的方面。
The configuration of online monitoring system for unit vibration of Huizhou Pumped-Storage Power Station was introduced herein. As the interferences to measurement signal are removed in the process of system debugging, the measurement data can accurately reflect the true state of the unit vibration. The vibration characteristics and dynamic balance tests of units are analyzed. Proposals on the dynamic balance test of pumped-storage unit are provided.
出处
《水力发电》
北大核心
2010年第9期76-78,共3页
Water Power
关键词
振动监测
干扰
动平衡
抽水蓄能机组
vibration monitoring
interference
dynamic balance
pumped-storage units