摘要
阐述了基于超高频法的GIS局部放电检测系统在抗干扰、局放信号识别等方面的优越性能。以南方电网下属某110kV变电站GIS局部放电监测系统的安装为例,介绍了这个系统的现场安装调试的具体细节,并提出基于超高频法的GIS局放在线检测是实现数字变电站的基础。
The outstanding features of anti-interference,PD signal identification of GIS partial discharge online monitor System Based on UHF Method is formulated.With the installation of such system in a 110kV substation of SCG as example,the details of site installation and debugging is introduced.It is pointed out that on-line GIS PD monitor system based on UHF method is the basis to succeed digital substation.
出处
《广东输电与变电技术》
2010年第5期27-30,共4页
Guangdong Power Transmission Technology