对臭氧预氧化工艺对水中藻类的去除进行了试验性研究,分析了臭氧预氧化的除藻效果,并探讨了其除藻机理。试验结果表明,预臭氧化可以明显地提高除藻效果,臭氧投量为1.5 mg/L时,除藻率达到最高值88.3%,继续增加投量,除藻率不再增高。
It makes experimental study on algae-removal in water with pre-oxidation technology,analyzes the algae-removal effect of pre-oxidation,and explores its algae-removal mechanism.The results show that pre-oxidation can significantly increase the effect of algae-removal,when the ozone dosage is 1.5 mg/L,the algae-removal rate reaches the highest value of 88.3%,if the ozone dosage continues to increase,the algae-removal rate will not raise any more.