期刊文献+

化学修饰型复合汞膜电极测定双黄连口服液中黄芩苷的含量

Determination of baicalin in Shuanghuanglian oral liquid on composite mercury film electrode based on chemical modfied
原文传递
导出
摘要 目的:利用铕离子掺杂普鲁士蓝(europium-doped prussian blue analogue,Eu-PB)化学修饰型复合汞膜电极(GC/Eu-PB/MFE)建立了黄芩苷的测定方法,并探讨了其电化学行为。方法:在BR(pH6.0)支持电解质中,采用差示脉冲伏安法(DPV)和循环伏安法(CV)。结果:GC/Eu-PB/MFE电极与传统玻碳汞膜电极(GC/MFE)相比,同浓度的黄芩苷在GC/Eu-PB/MFE上响应灵敏度高,重复性好。黄芩苷在该电极上表现较强的吸附行为,其还原峰电位为-1.22 V(vs SCE)。还原峰电流与黄芩苷浓度在8.0×10-9~1.0×10-6mol.L-1呈线性关系(r=0.999 2),检测下限为1.2×10?9mol.L-1(S/N=3)。不经预分离直接测定双黄连口服液中黄芩苷的含量,平均回收率为99.83%,平均RSD 2.3%(n=8)。结论:GC/Eu-PB/MFE用于双黄连口服液中黄芩苷含量的测定,检测限低、灵敏、可靠,可用于该制剂的质量控制。 Objective: A novel Eu-PB composite mercury film electrode(GC/Eu-PB/MFE)based on chemical modfied was developed for the determination of baicalin and the investigation of its the electrochemical behavior.Method: Cyclic voltammetry and differential pulse voltammetry were used.Result: The adsorption characteristic of baicalin was observed in Britton-Robinson buffer solution(pH 6.0)at GC/Eu-PB/MFE.The reduction peak of baicalin was observed at-1.22 V(vs SCE)and peak current was linear to the baicalin from 8.0×10^-9 to 1.0×10^-6 mol·L^-1(r=0.999 2,n=8).The limit of detection was 1.2×10^-9 mol·L^-1(S/N=3).The average recovery was 99.83%,with RSD of 2.3 %(n=8).The baicalin in Shuanghuanglian oral can be directly determined without pretreatment.Conclusion: The GC/Eu-PB/MFE was used to determin ebaicalin in Shuanghuanglian oral with good repeatability and high sensitivity.The method can be used for the quality control of Chinese traditional medicines containing Scutellaria baicalensis.
出处 《中国中药杂志》 CAS CSCD 北大核心 2010年第18期2399-2401,共3页 China Journal of Chinese Materia Medica
关键词 化学修饰电极 普鲁士蓝 复合汞膜电极 差示脉冲伏安法 黄芩苷 chemical modified electrode prussian blue composite mercury film differential pulse voltammetry baicalin
  • 相关文献

参考文献9

二级参考文献42

  • 1金利通,叶建山,方禹之.Nafion-MV修饰电极丙酮酸氧化酶生物传感器测定GPT的研究[J].高等学校化学学报,1993,14(9):1210-1213. 被引量:5
  • 2李南强,徐友宣.桑色素极谱行为的研究[J].物理化学学报,1993,9(2):175-180. 被引量:12
  • 3李建平,乐上旺.双硫腙修饰固体银汞合金电极吸附伏安法测定痕量铅[J].分析测试学报,2007,26(1):100-103. 被引量:14
  • 4BRETT C M A,BRETT A M O,MATYSIK F M,et al.Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry[J].Talanta,1996,43(11):2015-2022.
  • 5WOLFGANG F.Mercury film on a glass carbon support:attributes and problem[J].Anal Chim Acta,1993,273(1/2):123-137.
  • 6ECONOMOU A,FIELDEN P R.Mercury film electrodes:developments,trends and potentialities for electroanalysis[J].Analyst,2003,28:205-212.
  • 7ZEN Jyhmyng,CHUNG Hsiehhsun,ILANGOVAN G.Selective voltammetric determination of lead(Ⅱ) on partially quaternized poly(4-vinylpyridine)/mercury film electrodes[J].Electroanal,1999,11(2):108-113.
  • 8MONTERROSO S C C,CARAPUC H M,DUARTE A C.Mixed polyelectrolyte coatings on glassy carbon electrodes:Ion-exchange,permselectivity properties and analytical application of poly-L-lysine-poly(sodium 4-styrenesulfonate)-coated mercury film electrodes for the detection of trace metals[J].Talanta,2006,68(5):1655-1662.
  • 9MURIMBOH J,LAM M T,HASSAN N M,et al.A study of nafion-coated and uncoated thin mercury film-rotating disk electrodes for cadmium and lead speciation in model solutions of fulvic acid[J].Anal Chim Acta,2000,423(1):115-126.
  • 10CHRISTENSEN M K,HOYER B.Comparative study of conventional and cellulose acetate-coated mercury film electrodes for speciation of lead in the presence of humic acid[J].Electroanalysis,2000,12(1):35-38.

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部