期刊文献+

几种新型眼前节影像技术及临床应用 被引量:1

Advances in ocular anterior segment imaging
下载PDF
导出
摘要 以眼前节光学相干断层扫描(OCT)、Scheimpflug技术、高分辨率磁共振成像及裂隙扫描等为代表的眼前节影像技术提供了房角的各种参数,可测量角膜前后表面的曲率和前房内径,计算出角膜的屈光度,在准分子激光角膜原位磨镶术(LASIK)术后能够测量角膜瓣厚度,甚至可用于调节功能及老视的研究,极大地提高了诊疗水平。就几种新型眼前节影像技术的研究进展及其临床应用进行综述。 Anterior segment imaging technology is a rapidly advancing field in ophthalmology.New imaging modalities,such as anterior segment optical coherence tomography(OCT),Scheimpflug imaging and magnetic resonance imaging(MRI) have become commercially available.These technologies provide quantitative estimation for the parameters of cornea and anterior chamber by calculating the angle between the iris surface and the posterior corneal surface.The biological images of the scleral spur,ciliary body,ciliary sulcus also are exhibited by these useful tools.The net corneal power can be measured by Pentacam-Scheimpflug,and corneal flap depth following LASIK and anterior chamber width can be measured by anterior segment OCT.All of these devices may herald the dawn of a new era for ophthalmic diagnosis and therapy.
作者 尤宇一 袁非
出处 《眼科研究》 CSCD 北大核心 2010年第9期908-911,共4页 Chinese Ophthalmic Research
关键词 眼前节影像 光学相干断层扫描 SCHEIMPFLUG 磁共振成像 anterior segment imaging optical coherence tomography Scheimpflug magnetic resonance imaging
  • 相关文献

参考文献30

  • 1Goldsmith JA, Li Y, Chalita MR, et al. Anterior chamber width measurement by high-speed optical coherence tomography [ J ]. Ophthalmology,2005,112 (2) : 238 - 244.
  • 2Rabsilber TM, Khoramnia R, Auffarth GU. Anterior chamber measurements using Pentacam rotating Scheimpflug camera [ J ]. J Cataract Refract Surg,2006,32 ( 3 ) : 456 - 459.
  • 3Radhakrishnan S, Goldsmith J, Huang D, et al. Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles[ J]. Arch Ophthalmol,2005,123 ( 8 ) : 1053 - 1059.
  • 4Fea AM, Annetta F, Cirillo S, et al. Magnetic resonance imaging and Orbscan assessment of the anterior chamber [ J ]. J Cataract Refract Surg,2005,31 (9) : 1713 - 1718.
  • 5Bert RJ, Patz S, Ossiani M, et al. High-Resolution MR imaging of the human eye 2005 [ J ]. Acad Radiol,2006,13 (3) : 368 - 378.
  • 6Swartz T, Marten L, Wang M. Measuring the cornea: the latest developments in corneal topography [ J]. Curr Opin Ophthalmol,2007, 18(4) : 325 - 333.
  • 7Lee DH, Seo S, Shin SC, et al. Accuracy and predictability of the compensatory function of Orbscan Ⅱ in intraocular pressure measurements after laser in situ keratomileusis [ J ]. J Cataract Refract Surg, 2002,28 ( 2 ) : 259 - 264.
  • 8Tam ES, Rootman DS. Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy [ J ]. J Cataract Refract Surg, 2003,29 ( 6 ) : 1179 - 1184.
  • 9Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior segment imaging : a new era for ophthalmic diagnosis [ J] ? Br J Ophthalmol,2007,91 (4) : 551 - 557.
  • 10Lim K, Fam H. Relationship between the corneal surface and the anterior segment of the corneal: an Asian perspective [ J ]. J Cataract Refract Surg,2006,32(11 ) : 1814 - 1819.

同被引文献11

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部