复合氧化工艺对医用钛合金耐蚀性和耐磨性的影响 被引量:2

Effect of the Complex Oxidation on Wear and Corrosion Resistance of Biomedical Titanium Alloy
下载PDF
导出
摘要 采用阳极氧化和热氧化相结合的复合氧化工艺对医用钛合金进行氧化处理,研究了氧化液的组成和热氧化温度对钛合金氧化膜表面形貌,耐蚀性和耐磨性能的影响。实验结果表明,复合氧化工艺可以提高钛合金表面的耐蚀性能和弹性模量,改善了钛合金的耐磨损性能。 Complex oxidation,which composed by anodic oxidation and thermal oxidation,was carried out on biomedical titanium alloys. Effects of solution composition and thermal oxidation temperature on the surface morphology,corrosion and wear resistance of oxide films of the alloy were investigated. The results showed that the corrosion resistance and elastic modulus of biomedical titanium alloys were improved by this complex process. The wear resistance of titanium alloys was enhanced.
出处 《电镀与精饰》 CAS 北大核心 2010年第9期14-17,共4页 Plating & Finishing
关键词 医用钛合金 阳极氧化 热氧化 耐蚀性 耐磨性 biomedical titanium alloy anodic oxidation thermal oxidation corrosion resistance wear resistance
  • 相关文献

参考文献7

  • 1Geetha M,Singh A K,Asokamani R,et al.Ti based biomaterials,the ultimate choice for orthopaedic implants-A review[J].progress in Materials Science 2009,54:397-425.
  • 2Bloyce A,Qi P Y,Bell T.Titanium alloys for combined improvements in corrosion and wear resistance[J].Surf.Coat.Technol.1998,107:125-132.
  • 3Hasan Gulery uz,Huseyin,Cimenoglu.Effect of thermal oxidation on corrosion and corrosion-wear behaviour of a Ti-6A1-4V alloy[J].Biomaterials 2004,25:3325-3333.
  • 4Borgioli E,Galvanetto F,Iozzelli G.Improvement of wear resistance of Ti-6Al-4V alloy by means of thermal oxidation Pradelli[J].Materials Letters 2005,59:2159-2162.
  • 5Guleryuz H,Cimenoglu H.Surface modification of a Ti6Al-4V alloy by thermal oxidation[J].Surface & Coatings Technology 2005,192:164-170.
  • 6Siva D,Krishana R,Brama Y L,et al.Thick rutile layer on titanium for tribological applications[J].Tribol,2007,40.329-334.
  • 7王博.钛合金阳极化处理技术[J].航空制造技术,2009,52(10):137-138. 被引量:5

共引文献4