介绍了HL-2A装置ECRH系统传输效率的测量方法。通过对MOU、回旋管输出窗口及真空密封窗口吸收功率的测量,得到HL-2A电子回旋系统的传输效率为90%左右。提出了除由MOU处测量微波功率外,可以由传输线的其他部位确定功率的方法。
The method for measuring the transmission efficiency of the HL-2A ECRH system is presented.The efficiency is about 90% by measuring the microwave power absorbed calorimetrically in the MOU,gyrotronoutput window and torus window of the EC system.A method of measuring power through parts of thetransmission line besides MOU is provided.