期刊文献+

SWY11-2高精度小型测温仪 被引量:1

SWY11-2 High-precision and Small-size Thermometer
下载PDF
导出
摘要 介绍一种新型的SWY11-2高精度小型水温测量仪器。该仪器传感器的感温元件采用负温度系数(NTC)热敏电阻,它具有温度系数大、灵敏度高、热容量小、响应速度快、分辨率高和成本低的特点;电路系统使用24位A/D转换器、低功耗单片机,并通过充分开发芯片资源,提高系统电路集成度,从而达到体积小、功耗低、操作简单的特点;为了达到海上恶劣条件下快速操作,其结构还采用了无工具拆装的设计。仪器在海上现场与加拿大RBR公司的TR1060水温仪比测试验,结果证明仪器性能接近国外高精度产品的水平,SWY11-2型测温仪与进口同类仪器相比,具有成本低和服务方便的优势,今后定有广阔的应用前景。 The working principal and design scheme of a new-developed water temperature measuring instrument is introduced. The SWY11-2 thermometer has the advantages of high sensitivity, low thermal capacity, high response velocity, high resolution, etc. The circuit system uses 24 bit A/D converter and low power MCU. Tile frame design of SWY11-2 is "without tool" assembly suitable for marine applications. The intereomparison experiment with RBR TR 1060 is carried out on the sea, the results show that the performance of SWY11-2 is close to foreign high-precision product, while the cost is lower and the maintenance is more convenient.
作者 邵毅 李家顺
出处 《海洋技术》 北大核心 2010年第3期24-28,共5页 Ocean Technology
关键词 SWY11-2温度测量 测温仪 AD7714 SWY11-2 temperature measuring thermometer AD7714
  • 相关文献

参考文献3

二级参考文献12

  • 1[6]R.M.Hendry,Bedford Institute of Oceanography CTD trials. Canada Technical Report of Hydrography and Ocean Science, Apil 1992.
  • 2[7]Franccois Nyffeler et al..A practical comparison between Seabird SBE911 and Ocean Seven 320 CTD probes, University of Neuchtel, Switzerland, Jun 2002.
  • 3[9]P.J.H.SUTTON et al.. Absolute geotropic currents in the East Auckland Current region. New Zealand Journal of Marine and Freshwater Research,2002,36:751~762.
  • 4[10]Jeffrey Sherman et al.. Estimates of vertical wave-number-frequency spectra of vertical shear and strain.Journal of Physical Oceanography,1990.
  • 5[11]Gargett A.E.,Schmitt R.W.Observations of salt fingers in the central waters of the eastern North pacific. Journal of Geophysical Research,1982,87(C10).
  • 6[12]Jack Barth et al.. Sea Soar Observations During Coastal Mixing and Optics. College of Oceanic and Atmospheric Sciences, Oregon State University, 1997.
  • 7[13]Eric Firing. Lowered ADCP Development and Use in WOCE. International WOCE Newsletter, Number 30,March 1998.
  • 8张兆英.高精度CTD剖面仪研制中的问题和对策——SZC15CTD系统[J].海洋技术,2001,20(1):130-139. 被引量:7
  • 9王欣.高精度CTD剖面仪研制过程中的专用设备[J].海洋技术,2001,20(1):140-142. 被引量:3
  • 10吴明钰,李建国.高精度CTD剖面仪温度传感器[J].海洋技术,2001,20(1):143-146. 被引量:16