期刊文献+

大空间展览建筑热障效应对自然排烟的影响模拟 被引量:11

Simulation of heat barrier affecting natural smoke extraction in large-space building
下载PDF
导出
摘要 针对某大型展览中心标准展厅的自然排烟系统,通过FDS数值模拟,研究夏季展厅室内屋顶热障效应对自然排烟的影响,以及自然排烟系统的优化设计。结果表明:热障效应对较大规模火灾的自然排烟影响不大,对较小规模的火灾,初期热障效应对羽流上升起到延迟作用,导致排烟延迟;通过设置一定高度的挡烟垂壁将展厅划分为若干防烟分区,以及采用屋顶排烟结合高位侧窗排烟的方式可以减弱热障效应。 Aiming at the natural smoke extraction in some large exhibition center,and utilizing FDS,study the influence of roof heat barrier to natural smoke extraction,and optimize the design of natural smoke extraction system.Results show that: the heat barrier doesn't have much influence to the natural smoke extraction of big fire,but can delay the raise of plume and the smoke extraction if the fire is small;by setting smoke-proof pendent wall of some height dividing the exhibition room into several smoke compartment,and by roof combining high side windows smoke exhaustion,can weaken the heat barrier effect.
作者 胡浩
机构地区 合肥市消防支队
出处 《消防科学与技术》 CAS 北大核心 2010年第9期760-764,共5页 Fire Science and Technology
关键词 大空间建筑 热障效应 自然排烟 火羽流 FDS large-space building heat barrier effect natural smoke extraction fire plume FDS
  • 相关文献

参考文献5

二级参考文献12

  • 1W罗迪.湍浮力射流与羽流[M].北京:海洋出版社,1991..
  • 2范维澄 王清安 等.火灾简明学教程[M].合肥:中国科学技术大学出版社,1995..
  • 3杨世铭.传热学(第二版)[M].北京:高等教育出版社,1993..
  • 4MOWRER F W. Enclosure smoke filling revisited[J]. Fire Safety J,1999, 33: 93-114.
  • 5CHOW W K, LI Y Z, CUI E, et al. Natural smoke filling in atrium with liquid pool fires up to 1.6 MW[J]. Building and Environment,2001, 36: 121-127.
  • 6HESKESTAD G. Fire plume behavior in temperature-stratified ambients[J]. Combustion Sci and Tech, 1995, 106: 207-228.
  • 7MORTON B R, TAYLOR G, TURNER J S. Turbulent gravitational convection from maintained and instantaneous sources[ C ]// Proceedings of the Royal Society of London. London : The Royal Society, 1956, 234: 1-23.
  • 8NFPA. Guide for smoke management systems in malls, atria, and large areas NFPA 92B-2000[ R]. National Fire Protection Association,Quincy, MA, 2000.
  • 9FANGJun(方俊) SHUXueming(疏学明) YUANHongyong(袁宏永) etal.Solution of integral equations and experimental analysis of fire smoke plumes in stably linearly thermally stratified environments[J].中国工程科学,2004,1(6):37-43.
  • 10FAN Weicheng ( 范维澄 ). Guide of fire science ( 火灾科学导论 )[ M]. Wuhan: Hubei Science and Technology Press, 1993.