期刊文献+

经皮椎体成形术后骨水泥渗漏的影像学表现及相关因素探讨 被引量:5

Imaging findings and the investigation of related factors of bone cement leakage in percutaneous vertebroplasty
下载PDF
导出
摘要 目的:探讨经皮椎体成形术后骨水泥渗漏的X线征象及其相关因素与预防。方法:分析28例46椎经皮椎体成形术后患者的影像及临床资料,其中转移性肿瘤4例5椎,椎体血管瘤2例2椎,骨质疏松性压缩性骨折9例23椎,外伤性压缩性骨折13例16椎。结果:22例32椎出现骨水泥渗漏,渗漏率69.6%(32/46),静脉丛渗漏23椎,其中并发肺栓塞3例及下腔静脉骨水泥栓子1例,椎间盘渗漏4椎,针道渗漏8椎,椎旁软组织渗漏3椎,椎管内渗漏4椎。结论:经皮椎体成形术骨水泥渗漏率较高,术中加强监控及术后X线常规检查有利于尽早发现、处理骨水泥渗出,严格的掌握手术适应证及良好的手术技巧可减少并发症的发生。 Objective:To explore X-ray findings of the bone cement leakage and the causes and prevention of its occurrence in percutaneous vertebroplasty(PVP).Methods:To analyze the imaging and clinical data of 28 patients with 46 vertebrae which PVP was performed,including 4 cases of metastatic tumors with 5 vertebrae,2 cases of vertebral hemangioma with 2 vertebrae,9 cases of osteoporotic compression fractures with 23 vertebrae,13 cases of traumatic vertebral compression fracture with 16 vertebrae.Results:The bone cement leaked in 22 patients with 32 vertebrae,with leakage rate of 69.6%(32/46).There was venous plexus leakage in 23 vertebrae in which 3 cases were complicated with pulmonary and 1 case with inferior vena cava embolism,disc leakage in 4 vertebrae,needle tract leakage in 8 vertebrae,paraspinal soft tissue leakage in 3 vertebrae and spinal canal leakage in 4 vertebrae.Conclusion:Though the rate of bone cement leakage in PVP is much higher,strengthened intraoperative monitoring and postoperative X ray can be conducive to early detection of bone cement leakage position and prevention of the potential hazards,and strict surgical indications and good surgical technique can reduce the incidence of complications.
出处 《交通医学》 2010年第4期341-343,346,共4页 Medical Journal of Communications
基金 南通市社会发展科技计划(编号:S2008052)
关键词 经皮椎体成形术 骨水泥渗漏 影像 vertebroplasty bone cement leakage imaging
  • 相关文献

参考文献6

  • 1张亚东,陈豪杰,王嘉,蔡振宇,张向阳.对有骨水泥渗漏的经皮椎体成形术效果的临床分析[J].脊柱外科杂志,2007,5(3):141-144. 被引量:13
  • 2Bouza C,Lopez T,Magro A,et al.Efficacy and safety of balloon kyphoplasty in the treatment of vertebral.compression fractures:a systematic review[J].Eur Spine J,2006,15(7):1050-1067.
  • 3Mathis JM.Percutaneous vertebroplasty:complication avoidanee and technique optimization[J].Am J Neuroradiol,2003,24(8):1697-1706.
  • 4Ploeg WT,Veldhuizen AG,The B,et al.Percutaneous vertebroplasty as a treatment for osteoporotic vertebral compression fraetures:a systematic review[J].Eur Spine J,2006,15(12):1749-1758.
  • 5Pott L,Wippermann B,Hussein S,et al.PMMA pulmonary embolism and post interventional associated fractures after percutaneous vertebroplasty[J].Orthopade,2005,34(7):698-700.
  • 6Montieelli F,Meyer HJ,Tutsch-Bauer E.Fatal pulmonary cement embolism following percutaneous vertebroplasty(PVP)[J].Forensic sci Int,2005,149(1):35-38.

二级参考文献9

  • 1何仕诚,牛焕章,邓钢,滕皋军.经皮椎体成形术和后凸成形术并发症的对比分析[J].介入放射学杂志,2005,14(3):317-320. 被引量:11
  • 2[1]Nussbaum DA,Gillound P,Murphy K.A review of complicalion associated with vertebroplasty and kyphoplasty as reported to the Food and Drug Administration Medical Device related web site.JVIR,2004,15:1185-1192
  • 3[2]Mathis JM.Percutaneous vertebroplasty:complication avoidance and technique optimization.AJNR,2003,24:1697-1706
  • 4[3]Ryu KS,Park CK,Kim MC,et al.Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures.J Neurosurg,2002,96:56-61
  • 5[4]Cotton A.Dewatre F,Cortet B,et al.Percutaneous vertebroplasty for osteolytic metastases and myeloma:effects of the percentage of lesion filling and the leakage of methylmethacrylate at clinical follow-up.Radiology,1996,200:525-530
  • 6[5]Shapiro S,Abel T,Purvines S.Surgical removal of epidural and intradural polymethylmethacrylate extravasation complicating percutaneous vertebroplasty for an osteoporotic lumbar compression fracture.Case report.J Neurosurg,2003,98:90-92
  • 7[6]Stricker K,Orler R,Yen K,et al.Severe hypercapnia due to palmonary embolism of polymethylmethacrylale during vertebroplasty Anesth Analg,2004,98:1184-1186
  • 8[8]Scroop R,Eskridge J,Britz GW.Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty:a case rport.AJNR Am J Neuroradiol,2002,23:868-870
  • 9[9]Cotton A,Boutry N,Cortet B,et al.Percutaneous vetebraoplasty:state of the art(Review).Radiographics,1998,18:311-320

共引文献12

同被引文献48

引证文献5

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部