分析了自动喷水灭火系统在设计、施工中存在的问题,诸如喷淋泵流量设计、喷头选型、湿式报警阀组、水流指示器、末端试水装置、系统管网、系统增压设施在设计施工中的问题。同时,讨论了相关的规范和技术。最后指出,应加强湿式自动喷水灭火系统的设计与施工管理,确保其在火灾状况下发挥应有作用。
Problems existed in system design and construction of automatic water spray fire extinguishing system were analyzed, like related problems existed in flow design of spray pump, type selection of sprinkle nozzle, wet alarm valve group, water flow indicatory, end testing device, pipe network, supercharging facility in the progress of construction. Meanwhile, related stardards and technology were also discussed.
出处
《现代建筑电气》
2010年第8期34-37,共4页
Modern Architecture Electric
关键词
自动喷水灭火系统
喷淋泵
湿式报警阀组
automatic water spray fire extinguishing system
spray pump
wet alarm valve group