灯泡贯流泵房机组的橡胶垫减振措施研究

Study of damping measure with rubber buffers for bulb tubular pump-house
下载PDF
导出
摘要 针对南水北调东线工程大型灯泡贯流泵房的振动问题,首次提出采用橡胶垫减振的振动控制措施.采用经典减振理论进行减振设计,通过参数控制选择合适的橡胶垫,确定设计方案,采用Bouc-Wen微分型恢复力模型模拟橡胶垫的非线性滞回特性,利用MATLAB中的SIMULINK工具进行仿真分析,通过非线性计算验证方案的可行性.将橡胶垫减振措施应用于淮阴三站的减振设计,计算结果表明,采用减振措施后振动强度可降低50%以上. Vibration damping measure with rubber buffers is proposed for the first time to be applied to the vibration control of the large-scale bulb tubular pump-house in the eastern route of the South-to-North Water Transfer Project.Classical damping theory is used for damping design and suitable rubber buffers are selected through parameter control.Bouc-Wen hysteretic model is applied to simulate the nonlinear characteristics of rubber buffers.With simulation analysis based on SIMULINK of MATLAB,the number and the arrangement of rubber buffers are verified through nonlinear calculation.This damping method is used for the damping design of Huaiyin Third Pumping Station and vibration can be reduced by more than 50% after adopting the damping measure.
出处 《水利水运工程学报》 CSCD 北大核心 2010年第3期17-21,共5页 Hydro-Science and Engineering
基金 "十一五"国家科技支撑项目:大型贯流泵关键技术与泵站联合调度优化(2006BAB04A03)
关键词 灯泡贯流泵房 橡胶垫减振 Bouc-Wen非线性模型 仿真 bulb tubular pump-house vibration damping of rubber buffer Bouc-Wen nonlinear model simulation
  • 相关文献

参考文献16

  • 1孙洪斌,鲁靖华,郑源,闵志运.淮安三站大型贯流机组运行存在问题及分析[J].水泵技术,2007(5):36-40. 被引量:6
  • 2董毅,吕省三.大型虹吸式轴流泵站启动振动原因分析[J].江苏水利,2001,17(4):25-26. 被引量:3
  • 3ABDEL-RAHMAN S M,HELAL M A,NASSER M A.Vibration problems of axial flow pump[C] ∥Proceedings of the International Modal Analysis Conference,2000,V1:891-898.
  • 4AWASTHI J P.Vibration problem of large capacity pumps-a case study[J].Journal of Indian Water Works Association,1987,19(4):287-294.
  • 5ORTWIG H.Experimental and analytical vibration analysis in fluid power systems[J].International Journal of Solids and Structures,2005,42(21-22):5821-5830.
  • 6MINISCI E,TELIB H,GIANCARLO C.Hydraulic design validation of the suction intake of a vertical centrifugal pump station,by use of computational fluid dynamic (CFD) analysis[C] ∥Proceedings of 2005 ASME Fluids Engineering Division Summer Meeting(FEDSM2005),USA:Houston,2005:1512-1523.
  • 7BEEKMAN B.Resonant vibrations in vertical pumps[J].World Pumps,2004(458):18.
  • 8WHEATLEY S.Using pulsation dampers to reduce pipework vibrations[J].World Pumps,2002(424):32-35.
  • 9WALSH P L,LAMANCUSA J S.A variable stiffness vibration absorber for minimization of transient vibrations[J].Journal of Sound and Vibration,1992,158(2):195-211.
  • 10郑建国,姚志远,孙培林.水泵房噪声综合治理[J].噪声与振动控制,1998,18(3):34-35. 被引量:7